{"product_id":"foxboro-invensys-p0917xv-termination-assembly","title":"Foxboro Invensys P0917XV Termination Assembly","description":"\u003cp\u003eConfigured for signal termination and field distribution in I\/A Series control networks, the \u003cstrong\u003eFoxboro Invensys P0917XV\u003c\/strong\u003e (\u003cstrong\u003eP0917XV\u003c\/strong\u003e Termination Assembly) provides direct physical\/electrical execution. This hardware component serves as the primary interface for managing 8 isolated output channels, specifically designed to facilitate 4-20 mA DC control loops and superimposed HART digital communication between field actuators and the controller backplane.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eP0917XV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro Invensys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eManufacturer Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e14.5 cm x 13.5 cm x 6.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (Loop powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Configuration\u003c\/td\u003e\n\u003ctd\u003e8 Isolated Output Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Load\u003c\/td\u003e\n\u003ctd\u003e750 Ohm at 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e600 V AC per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Instrumentation Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe P0917XV maintains signal integrity through rigorous channel-to-channel isolation architecture. By utilizing a high-density 3-tier compression terminal design, the assembly suppresses signal noise and ensures consistent impedance for HART loop protocol communication. The physical layout supports 4-20 mA HART loop protocol standards, allowing for reliable field device interrogation and partial stroke testing. The assembly adheres to ISA Standard S71.04 Class G3 requirements, ensuring performance consistency within harsh, corrosive industrial environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the P0917XV support hot-swap capabilities for the FBM215 and FBM218 modules?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the mechanical design of the terminal assembly allows for the removal and replacement of FBM modules without disrupting field wiring, provided the I\/A Series system is in a controlled maintenance state.\u003c\/p\u003e\n\u003cp\u003eQ: Are there specific cabling distance limitations for HART digital signals through this assembly?\u003c\/p\u003e\n\u003cp\u003eA: The P0917XV supports signal transmission distances up to 3,000 meters for HART digital messaging, contingent upon the use of shielded, low-capacitance twisted-pair cabling to minimize signal attenuation.\u003c\/p\u003e\n\u003cp\u003eQ: What is the requirement for redundant FBM218 configurations?\u003c\/p\u003e\n\u003cp\u003eA: While the P0917XV serves as the termination base, utilizing the FBM218 in a redundant pair requires an additional adapter (e.g., RH916QD) to correctly bridge the dual-module signals across the 8-channel interface.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the P0917XV assembly onto the standard DIN-rail within the I\/O cabinet, ensuring sufficient clearance for heat dissipation and cable management.\u003c\/li\u003e\n\u003cli\u003eTerminate field wiring using the compression-style screw terminals; ensure all conductors are seated firmly to prevent high-resistance contact points.\u003c\/li\u003e\n\u003cli\u003eFor shielding, terminate the cable drain wires to the designated grounding bus bar to maintain the 600 V AC galvanic isolation rating per channel.\u003c\/li\u003e\n\u003cli\u003eVerify the compatibility of the FBM module (FBM215 or FBM218) before seating the module into the terminal assembly backplane connector.\u003c\/li\u003e\n\u003cli\u003eAfter installation, perform a loop check using the Foxboro Intelligent Field Device Configurator (IFDC) to confirm HART communication stability before commissioning the output loop.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":53028039950645,"sku":"FBM215\/218 P0917XV","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/FBM215218P0917XV.png?v=1782202919","url":"https:\/\/www.5gplc.com\/products\/foxboro-invensys-p0917xv-termination-assembly","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}