{"product_id":"foxboro-igp10-a22d1f-pressure-transmitter","title":"Foxboro IGP10-A22D1F Pressure Transmitter","description":"\u003cp\u003eThe \u003cstrong\u003eFoxboro IGP10-A22D1F\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIGP10\u003c\/strong\u003e Pressure Transmitter, operates as a dedicated hardware component for gauge pressure measurement and signal conversion within Foxboro I\/A Series system loops. It measures process fluid pressures up to 300 psi and outputs a 2-wire 4-20 mA analog signal proportional to the calibrated span.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIGP10-A22D1F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro (Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.20 lbs (Approx. 1.45 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard gauge pressure transmitter profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial transmitter operating limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLoop-powered via 12.5 to 42 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e2-wire 4-20 mA analog output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Range\u003c\/td\u003e\n\u003ctd\u003e0 to 25 psi (Span limits up to 300 psi MWP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eFoxboro I\/A Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA Loop Architecture and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eFoxboro IGP10-A22D1F\u003c\/strong\u003e transmits process variable measurements over a standard 2-wire 4-20 mA current loop to host I\/A Series Fieldbus Modules (FBM). Internal piezoresistive sensing circuitry utilizes channel-to-channel isolation and integrated signal conditioning to mitigate common-mode noise across industrial field loops. The transmitter circuitry maintains stable analog signal response under fluctuating supply voltages (12.5 to 42 VDC), ensuring zero-drift voltage regulation across DCS interface channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power source voltage range is required to operate the IGP10-A22D1F transmitter?\u003c\/p\u003e\n\u003cp\u003eA: The transmitter operates on a 2-wire loop supply voltage ranging from 12.5 VDC to 42 VDC connected across its terminal block.\u003c\/p\u003e\n\u003cp\u003eQ: How is the 4-20 mA loop protected against electrical ground loops during installation?\u003c\/p\u003e\n\u003cp\u003eA: The transmitter electronics housing maintains internal isolation between signal terminals and the metallic enclosure; cable shields should be grounded at the DCS panel end only.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum working pressure rating for the IGP10-A22D1F gauge sensor?\u003c\/p\u003e\n\u003cp\u003eA: The sensor element supports continuous operation across a calibrated range of 0 to 25 psi with a maximum working pressure rating up to 300 psi.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThread the pressure transmitter directly into the process piping or manifold using standard NPT pipe thread engagement procedures.\u003c\/li\u003e\n\u003cli\u003eRoute the 2-wire signal cable through grounded metal conduit, keeping signal lines isolated from high-voltage AC cabling.\u003c\/li\u003e\n\u003cli\u003eVerify that external DC loop supply voltage at the transmitter terminals does not drop below 12.5 VDC under a full 20 mA output condition.\u003c\/li\u003e\n\u003cli\u003eTerminate the cable shield drain wire directly to the instrument earth bar in the control cabinet to prevent EMI interference.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":53349302599989,"sku":"IGP10-A22D1F","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/IGP10-A22D1F.png?v=1787211548","url":"https:\/\/www.5gplc.com\/products\/foxboro-igp10-a22d1f-pressure-transmitter","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}