{"product_id":"foxboro-fcm100et-p0926gs-i-a-series-communication-module","title":"Foxboro FCM100ET P0926GS I\/A Series Communication Module","description":"\u003cp\u003eConfigured for Ethernet to fieldbus data bridging in Foxboro I\/A Series DCS networks, the \u003cstrong\u003eFoxboro FCM100ET P0926GS\u003c\/strong\u003e (\u003cstrong\u003eFCM100ET\u003c\/strong\u003e Communication Module) provides direct physical\/electrical execution. It handles protocol translation and data routing between high-speed 100 Mbps Ethernet infrastructures and 2 Mbps fieldbus communication loops.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFCM100ET\u003c\/strong\u003e: Base catalog designation for the Foxboro fieldbus communication module platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eP0926GS\u003c\/strong\u003e: Specific manufacturing part identifier and hardware revision suffix defining physical assembly and regional configuration parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFCM100ET (P0926GS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eLength: 100 mm, Width: 70 mm, Height: 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNominal DCS Backplane Power Rails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eEthernet to Fieldbus communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Transfer Rate\u003c\/td\u003e\n\u003ctd\u003e100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFieldbus Transfer Rate\u003c\/td\u003e\n\u003ctd\u003e2 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003eEthernet, RS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module manages critical signal pathways linked to distributed field instrumentation. By ensuring robust channel-to-channel isolation and galvanic separation, it prevents ground loops and transient voltage spikes from traversing between Ethernet backbone links and underlying 4-20 mA HART loop protocol loops. This isolation framework protects controller ports and preserves measurement integrity across harsh industrial process environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the FCM100ET P0926GS support hot-swapping on active DCS baseplates?\u003c\/p\u003e\n\u003cp\u003eA: Hot-insertion capability depends on the specific system cabinet power policy; always verify local safety protocols and de-energize segment power prior to handling hardware.\u003c\/p\u003e\n\u003cp\u003eQ: What are the maximum data transfer rates supported by the communication interfaces?\u003c\/p\u003e\n\u003cp\u003eK: The Ethernet interface operates at 100 Mbps, while the fieldbus communication loop operates at a transfer rate of 2 Mbps.\u003c\/p\u003e\n\u003cp\u003eQ: What physical communication ports are available on the module?\u003c\/p\u003e\n\u003cp\u003eA: The unit features physical interfaces for Ethernet networks and RS-485 serial communication loops.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure the installation slot is clean and free of particulate debris before mounting. Align the module housing carefully with the baseplate guide rails to prevent bending the backplane pins during insertion. Secure any retention screws firmly and verify that all communication cables are strain-relieved and properly shielded to prevent electromagnetic interference.\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":67693393183029,"sku":"FCM100ET P0926GS","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/FCM100ETP0926GS_Cocoai.png?v=1791949108","url":"https:\/\/www.5gplc.com\/products\/foxboro-fcm100et-p0926gs-i-a-series-communication-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}