{"product_id":"foxboro-fbm218-p0922vw-i-a-series-hart-communication-redundant-output-interface-module","title":"Foxboro FBM218 P0922VW I\/A Series HART Communication Redundant Output Interface Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFoxboro FBM218 (P0922VW)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprovides high-integrity HART digital communication and analog output capabilities for the Foxboro I\/A Series Distributed Control System (DCS). This module features eight isolated output channels designed to interface with smart field devices such as valve positioners and actuators. It bridges the gap between the DCS control database and the field, enabling both primary variable control and advanced asset management through HART data passthrough. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your critical control loops operate with factory-certified precision and zero previous field runtime.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFoxboro (by Schneider Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFBM218\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eP0922VW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInterface Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Isolated Output Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eHART Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHART Specifications Version 5, 6, or 7\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Strength\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e600 V AC (1 minute) channel-to-earth\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Method\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGalvanic (Optical and Transformer Isolation)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFieldbus Speed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 Mbps HDLC Redundant Fieldbus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +70°C (-4 to +158°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions (LxWxH)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.4 cm x 4.5 cm x 11.4 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.284 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe FBM218 P0922VW resolves critical signal integrity and availability challenges in complex processing plants:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTriple-Layer Galvanic Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module incorporates both optical and transformer isolation between individual channels, ground, and logic circuitry. This architecture repels electromagnetic interference (EMI) and prevents ground loops from corrupting the 4-20mA signal or the superimposed HART digital data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUninterrupted Redundant Communication:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware maintains constant contact with the associated FCM or FCP via a high-speed 2 Mbps HDLC redundant Fieldbus. This dual-path architecture ensures the DCS retains control over field actuators even if a primary communication path fails.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUniversal HART Tool Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSupporting HART versions 5, 6, and 7, the FBM218 allows engineers to execute remote calibration, diagnostics, and configuration of smart field instruments directly from the DCS workstation. This eliminates the need for technicians to use handheld communicators in hazardous field areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Transient Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe internal circuitry withstands a potential of 600 V AC applied for one minute between channels and earth. This protects the module logic from catastrophic damage during lightning strikes or major electrical faults in the plant's power distribution system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStreamlined Maintenance Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe compact 4.5 cm width optimizes rail space in high-density I\/O cabinets. The \"hot-swap\" capability allows for the immediate replacement of modules without disrupting the power or communication of neighboring units on the same baseplate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the FBM218 P0922VW support both input and output HART signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo, the FBM218 specializes in output interface tasks. It drives field devices like valve positioners. For HART input requirements (such as transmitters), you should utilize the corresponding FBM217 or similar input-specific modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this module with older HART Version 5 instruments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The FBM218 maintains full backward compatibility. It supports HART instruments compliant with Version 5, 6, or 7 of the HART specifications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I ensure the module condition is factory-fresh?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe guarantee every unit is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e. Each module arrives in original Foxboro factory-sealed packaging, ensuring all internal capacitors and semiconductors meet their full theoretical Mean Time Between Failures (MTBF) without degradation from previous use.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the Termination Assembly (TA) included in the module temperature rating?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module itself operates up to +70°C (+158°F). However, if you use a PVC-based Termination Assembly, you must limit the ambient temperature at the TA to +50°C (+122°F) to prevent material degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":52515751952693,"sku":"FBM218 P0922VW","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/FBM218P0922VW.jpg?v=1774938271","url":"https:\/\/www.5gplc.com\/products\/foxboro-fbm218-p0922vw-i-a-series-hart-communication-redundant-output-interface-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}