{"product_id":"foxboro-fbm214-216-p0916bx-terminal-assembly","title":"Foxboro FBM214\/216 P0916BX Terminal Assembly","description":"\u003cp\u003eConfigured for signal termination and interface distribution in Foxboro I\/A Series control networks, the \u003cstrong\u003eFoxboro Invensys P0916BX\u003c\/strong\u003e (\u003cstrong\u003eP0916BX\u003c\/strong\u003e Terminal Assembly) provides direct physical\/electrical execution. This component serves as the mechanical termination point for FBM214 and FBM216 field bus modules, facilitating the transition between field wiring and internal I\/O circuitry via standardized compression terminals.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eP0916BX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro Invensys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DIN-rail mount form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (no active electronic power draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Modules\u003c\/td\u003e\n\u003ctd\u003eFBM214, FBM216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Type\u003c\/td\u003e\n\u003ctd\u003eCompression Screw \/ Spring Clamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Instrumentation Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe P0916BX ensures signal integrity within the DCS infrastructure through optimized termination geometry. The assembly supports 4-20 mA HART loop protocol connectivity by providing dedicated test points and low-impedance paths for field instrumentation. The design incorporates channel-to-channel isolation physical barriers to minimize noise ingress and crosstalk during high-density signal integration. Field wires must be routed to prevent mechanical stress on the compression terminals, ensuring long-term connection stability in high-vibration control room environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the P0916BX terminal assembly support hot-swap operations for the connected FBM214\/216 modules?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the mechanical design of the P0916BX allows for the removal and replacement of the associated FBM modules without requiring the disconnection of field wiring from the terminal assembly, provided the system bus power is managed according to site safety protocols.\u003c\/p\u003e\n\u003cp\u003eQ: Are there specific torque requirements for the compression terminals?\u003c\/p\u003e\n\u003cp\u003eA: Yes, ensure all field wires are secured within the compression terminals to a torque specification of 0.5 Nm to 0.7 Nm to maintain electrical contact and prevent thermal cycling failures.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the DIN-rail is securely mounted to the cabinet backplane and electrically bonded to the common ground bus.\u003c\/li\u003e\n\u003cli\u003eAlign the P0916BX assembly with the rail and apply downward pressure until the latch mechanism engages.\u003c\/li\u003e\n\u003cli\u003eStrip field wires to the specified length (typically 8 mm to 10 mm) to ensure full contact within the compression housing without exposing excess copper.\u003c\/li\u003e\n\u003cli\u003eVerify that the shield drain wires are terminated at the designated grounding bar to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eConfirm the alignment of the FBM214\/216 backplane connector before applying pressure to seat the module onto the P0916BX assembly.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":53028029890869,"sku":"FBM214\/216 P0916BX","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/FBM214216P0916BX.png?v=1782202695","url":"https:\/\/www.5gplc.com\/products\/foxboro-fbm214-216-p0916bx-terminal-assembly","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}