{"product_id":"foxboro-fbm206-p0916cq-i-a-series-8-channel-pulse-input-module","title":"Foxboro FBM206 P0916CQ I\/A Series 8-Channel Pulse Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFoxboro FBM206 (P0916CQ)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-precision frequency acquisition interface for the Foxboro I\/A Series Distributed Control System (DCS). This module features eight isolated channels specifically designed to measure the rate of change or frequency of process variables. It serves as the primary hardware interface for turbine flowmeters, tachometers, and high-speed event counters. We provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring your control system maintains factory-certified accuracy without the degradation risks of refurbished components.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification Details\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFoxboro (Schneider Electric)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFBM206\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eP0916CQ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Independent Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePulse \/ Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 Hz to 20 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±0.5% of Full Scale\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 kΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2,500 Vrms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to 85 °C (-40 to 185 °F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e160 x 108 x 25 mm (6.25 x 4.25 x 1.0 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg (1.0 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe FBM206 P0916CQ resolves critical signal processing challenges in high-speed industrial environments:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Electrical Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEach channel provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2,500 Vrms isolation\u003c\/strong\u003e. This robust barrier prevents high-voltage transients and ground loops from entering the system Fieldbus, safeguarding the central control processors from field-side electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExtreme Thermal Tolerance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe hardware operates across a wide range from\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e-40 to 85 °C\u003c\/strong\u003e. This industrial-grade rating permits installation in remote marshalling cabinets or outdoor enclosures where temperature fluctuations would cause standard commercial electronics to fail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBroad Frequency Dynamics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module handles signals from ultra-low\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e0.5 Hz\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eup to high-speed\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20 kHz\u003c\/strong\u003e. This range allows engineers to use a single module type for diverse applications, from slow-turning volumetric flowmeters to high-speed turbine shafts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimal Thermal Load:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDrawing only\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2.5 W\u003c\/strong\u003e, the FBM206 generates negligible heat. This low-power consumption allows for high-density mounting on DIN rails or baseplates without necessitating specialized cabinet cooling systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTransparent Signal Acquisition:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh input impedance (100 kΩ) prevents the module from loading the field transmitter circuit. This ensures that the pulse signal maintains its peak voltage and wave shape, resulting in precise frequency calculations even over long cable runs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the FBM206 P0916CQ handle signals from magnetic pickups?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The FBM206 processes standard pulse and frequency signals commonly generated by magnetic sensors and turbine meters. You must verify that the peak-to-peak voltage of the sensor output meets the minimum threshold requirements of the I\/A Series Fieldbus specification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this module support hot-swapping?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe I\/A Series architecture allows for the removal and replacement of FBMs without powering down the baseplate. The system automatically re-identifies the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBrand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eP0916CQ and resumes data transmission via the redundant Fieldbus upon seating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the module deal with high-frequency noise?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe FBM206 incorporates internal signal conditioning and filtering. This hardware-level processing rejects high-frequency interference and \"jitter,\" ensuring the control processor receives only the true pulse data from the field device.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the P0916CQ compatible with older 100 Series baseplates?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe P0916CQ belongs to the 200 Series modular family. It requires a 200 Series baseplate for physical and electrical connection. If you are upgrading from 100 Series hardware, ensure you have the appropriate adapter or baseplate hardware in place.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":52514548154677,"sku":"FBM206 P0916CQ","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/FBM206P0916CQ.jpg?v=1774936700","url":"https:\/\/www.5gplc.com\/products\/foxboro-fbm206-p0916cq-i-a-series-8-channel-pulse-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}