{"product_id":"foxboro-d0162lq-h-lcd-indicator-module","title":"Foxboro D0162LQ\/H LCD Indicator Module","description":"\u003cp\u003eThe \u003cstrong\u003eFoxboro D0162LQ\/H\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eD0162LQ\u003c\/strong\u003e LCD Indicator Module, operates as a dedicated hardware component for visual process telemetry rendering and local status indication within Mesh Control Network-100 Mbps platforms. Functioning as an FCM100E series control accessory, it receives digital network data streams and drives the local liquid crystal display to present field variables without disrupting node processing loops. The unit complies with ISA S71.04 Class G3 harsh environment standards to withstand corrosive atmospheric contaminants.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eD0162LQ\/H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.37 lbs (0.17 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard FCM100E Module Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Temperature Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eBaseplate Backplane Powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Speed\u003c\/td\u003e\n\u003ctd\u003e100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Compliance\u003c\/td\u003e\n\u003ctd\u003eISA S71.04 Class G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eFCM100E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Control and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe Foxboro D0162LQ\/H module integrates channel-to-channel isolation barriers and high-speed bus interfaces to isolate internal display logic from field-induced electrical noise. Designed to interface with 4-20 mA HART loop protocol networks and 100 Mbps Mesh Control Network structures, the hardware buffers real-time visual variables while maintaining signal integrity across the backplane. The isolated internal architecture prevents ground loops and noise propagation from affecting primary field I\/O processing nodes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the D0162LQ\/H module be installed or replaced while the baseplate is powered?\u003c\/p\u003e\n\u003cp\u003eA: Yes, hot-swapping is supported provided standard Foxboro online insertion procedures are followed and electrostatic discharge protections are maintained.\u003c\/p\u003e\n\u003cp\u003eQ: How does the Class G3 rating impact module performance in industrial environments?\u003c\/p\u003e\n\u003cp\u003eA: The ISA S71.04 Class G3 compliance ensures internal circuit boards feature conformal coating to resist airborne contaminants, hydrogen sulfide, and chlorine corrosion.\u003c\/p\u003e\n\u003cp\u003eQ: What network interface protocol is required for visual data refresh on the indicator?\u003c\/p\u003e\n\u003cp\u003eA: The module communicates directly via the 100 Mbps Mesh Control Network interface embedded within the FCM100E series baseplate architecture.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify baseplate slot keying matches the FCM100E form factor prior to inserting the module card edge.\u003c\/li\u003e\n\u003cli\u003eAlign the rear connector pins with the backplane receptacle and press evenly until the retention clips latch securely.\u003c\/li\u003e\n\u003cli\u003eEnsure the cabinet earth ground wire is properly connected to the baseplate ground bar to maintain ISA Class G3 shielding integrity.\u003c\/li\u003e\n\u003cli\u003eKeep network bus cabling routed away from high-voltage AC conductors to reduce electromagnetic interference on the 100 Mbps communication lines.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":53406222975285,"sku":"D0162LQ\/H","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/D0162LQH.png?v=1787726303","url":"https:\/\/www.5gplc.com\/products\/foxboro-d0162lq-h-lcd-indicator-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}