{"product_id":"fc-tsro-08uni-honeywell-field-termination-assembly-module","title":"FC-TSRO-08UNI | Honeywell Field Termination Assembly Module","description":"\u003cp\u003eConfigured for relay-driven digital output switching in Safety Manager control architectures, the \u003cstrong\u003eHoneywell FC-TSRO-08UNI\u003c\/strong\u003e (\u003cstrong\u003eFC-TSRO-08UNI\u003c\/strong\u003e Field Termination Assembly Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe FC-TSRO-08UNI designation represents an 8-channel universal relay digital output field termination assembly variant. No complex internal sub-variant matrix applies to this standard catalog release, ensuring uniform form and function across established cabinet wiring layouts.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-TSRO-08UNI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eOEM Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg (Shipping Weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Field Termination Assembly Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via 24 VDC Loop Rails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal \/ Max Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC \/ 36 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Pick-Up Voltage\u003c\/td\u003e\n\u003ctd\u003e19.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Output Channels\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Current\u003c\/td\u003e\n\u003ctd\u003e2 A (fused)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Output Current\u003c\/td\u003e\n\u003ctd\u003e1 mA at 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Output Voltage\u003c\/td\u003e\n\u003ctd\u003e250 VAC \/ 250 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDigital Output Field Termination Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Loop Protocol\u003c\/h3\u003e\n\u003cp\u003eThe termination assembly incorporates galvanic channel-to-channel isolation across its 8 relay output channels to prevent electrical faults and ground loops from compromising control backplane integrity. 4-20 mA HART loop protocol compatibility provisions and robust relay switching circuits ensure precise actuator and interlock control under 250 VAC or 250 VDC maximum load parameters, while fused protection (up to 2 A per channel) safeguards against overcurrent conditions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the relay activation and input voltage thresholds for this module?\u003c\/p\u003e\n\u003cp\u003eA: The module operates at a nominal input voltage of 24 VDC (with a maximum of 36 VDC) and requires a minimum relay pick-up voltage of 19.2 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: What are the load limits for the 8 output relay channels?\u003c\/p\u003e\n\u003cp\u003eA: Each channel supports a maximum output current of 2 A (fused) and a maximum switching voltage of 250 VAC or 250 VDC, with a minimum current rating of 1 mA at 5 V.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDe-energize all external power sources and verify zero voltage across all terminal blocks prior to handling or wiring.\u003c\/li\u003e\n\u003cli\u003eMount the termination assembly securely onto the designated cabinet rail or mounting plate, ensuring a solid mechanical connection to the system earth ground.\u003c\/li\u003e\n\u003cli\u003eTerminate external field actuator and relay lines to the appropriate screw terminals, maintaining proper wire routing separation from low-level signal circuits.\u003c\/li\u003e\n\u003cli\u003eVerify input voltage thresholds and relay switching continuity before restoring power to the safety loop.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":52427502715189,"sku":"FC-TSRO-08UNI","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/FC-TSRO-08UNI.jpg?v=1773210857","url":"https:\/\/www.5gplc.com\/products\/fc-tsro-08uni-honeywell-field-termination-assembly-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}