{"product_id":"fc-pdb-0824-v1-0-honeywell-power-distribution-board","title":"FC-PDB-0824 V1.0 Honeywell Power Distribution Board","description":"\u003cp\u003eConfigured for 24 VDC power distribution in DCS cabinet assemblies, the \u003cstrong\u003eHoneywell FC-PDB-0824 V1.0\u003c\/strong\u003e (\u003cstrong\u003eFC-PDB-0824P V1.0\u003c\/strong\u003e Power Distribution Board) provides direct physical\/electrical execution. It allocates isolated power tracks to critical peripheral loads, such as fan units and Field Termination Assemblies (FTAs).\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFC-PDB-0824P V1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.26 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.8 x 22.5 x 17.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive distribution (Internal bus draw \u0026lt; 50 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Connector\u003c\/td\u003e\n\u003ctd\u003eWeidmuller BVZ 7.62\/02F SW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 protected outputs (Out1-Out8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Protection\u003c\/td\u003e\n\u003ctd\u003e2 A fusing per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Connectors\u003c\/td\u003e\n\u003ctd\u003eWeidmuller BL 5.08\/2 SN OR compatible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterconnect Cable\u003c\/td\u003e\n\u003ctd\u003eHoneywell PDC-MB24-x series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN-rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control \u0026amp; DCS Power Distribution Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe FC-PDB-0824 V1.0 power distribution architecture incorporates dedicated channel-to-channel isolation and individual branch overcurrent protection. By routing incoming 24 VDC feeder lines through eight discrete fused paths, the module prevents localized field short circuits from pulling down the main control loop supply rail. Channel status is monitored visually via onboard LED indicators mapped directly across each fuse terminal, providing clear hardware-level diagnostics without adding latency to the upstream Experion PKS system bus.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum current rating per output channel on the FC-PDB-0824 V1.0 board?\u003c\/p\u003e\n\u003cp\u003eA: Each individual output channel (Out1 through Out8) is equipped with a 2 A fuse rating. Loads exceeding 2 A on a single channel will open the respective fuse without disrupting voltage supply to the remaining seven output channels.\u003c\/p\u003e\n\u003cp\u003eQ: Are the input and output connectors hot-swappable under powered cabinet conditions?\u003c\/p\u003e\n\u003cp\u003eA: While the heavy-duty Weidmuller screw\/plug terminals permit mechanical disconnection, live plugging or unplugging under load must be limited to prevent arcing across the connector pins. De-energizing the main 24 VDC feeder prior to servicing individual power channels is recommended.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Mounting\u003c\/strong\u003e: Securely latch the module onto a standard 35 mm DIN rail inside the enclosure. Ensure top and bottom clear space of at least 50 mm for optimal convective airflow across the assembly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Wiring\u003c\/strong\u003e: Connect the main 24 VDC power input feeds to the Weidmuller BVZ 7.62\/02F SW header. Confirm correct wire polarity and torque wire clamp screws to 0.5-0.6 Nm.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding \u0026amp; Grounding\u003c\/strong\u003e: Bond the cabinet ground rail directly to the local enclosure earth point using a heavy-gauge copper braid. Keep DC power cables physically separated from high-voltage AC routing channels to minimize inductive cross-talk.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Distribution\u003c\/strong\u003e: Connect field peripherals and FTAs to output terminals Out1 through Out8 using Weidmuller BL 5.08\/2 SN compatible socket blocks. Validate individual channel current loads prior to inserting fuses and applying primary voltage.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53493212938549,"sku":"FC-PDB-0824 V1.0","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/FC-PDB-0824P__2_0ed44d26-8e4e-4eac-a770-64b5920f6d5b.jpg?v=1788830929","url":"https:\/\/www.5gplc.com\/products\/fc-pdb-0824-v1-0-honeywell-power-distribution-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}