{"product_id":"fbm228-p0922qs-analog-input-module-foxboro","title":"FBM228 P0922QS Analog Input Module | Foxboro","description":"\u003cp\u003eConfigured for precision current signal acquisition in I\/A Series control networks, the \u003cstrong\u003eFoxboro FBM228 P0922QS\u003c\/strong\u003e (\u003cstrong\u003eP0922QS\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution. This hardware component serves as the primary interface for 8 galvanically isolated channels, facilitating the transmission of 4-20 mA current loop signals from field instrumentation to the control platform.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFBM228 P0922QS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eManufacturer Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard I\/A Series module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e8 isolated analog inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e250 Ohm nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.05% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Instrumentation Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe FBM228 module ensures signal integrity within the DCS infrastructure through dedicated channel-to-channel isolation and channel-to-ground galvanic isolation. This architecture effectively suppresses common-mode noise and prevents ground loop currents from affecting the 4-20 mA HART loop protocol precision. The 15-bit resolution ensures high-fidelity data conversion for process variables, while the nominal 250 Ohm input impedance facilitates standard loop loading characteristics. Integration requires external 24 VDC loop power to satisfy the excitation requirements of the connected field sensors.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the FBM228 module support hot-swap maintenance procedures?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module is designed for extraction and insertion within the modular baseplate assembly. Ensure that field wiring power is disconnected in accordance with site safety protocols before removing the module to prevent electrical damage.\u003c\/p\u003e\n\u003cp\u003eQ: Is the FBM228 compatible with loop-powered and self-powered 4-20 mA transmitters?\u003c\/p\u003e\n\u003cp\u003eA: The module supports both configurations provided the external 24 VDC loop power supply is correctly routed through the termination assembly to provide the necessary excitation voltage for loop-powered devices.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the module onto the I\/A Series baseplate, ensuring the connector pins are aligned and fully seated to prevent communication faults.\u003c\/li\u003e\n\u003cli\u003eTerminate all 4-20 mA field signals using shielded, twisted-pair cabling to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eLand cable shield drain wires at the designated system grounding bar to maintain the efficacy of the galvanic isolation.\u003c\/li\u003e\n\u003cli\u003eVerify the 24 VDC loop power supply polarity at the termination block before energizing the field instruments.\u003c\/li\u003e\n\u003cli\u003ePerform a loop check via the control software to verify that the digitized input values correspond to the 4-20 mA current inputs across all 8 channels.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":53028128227637,"sku":"FBM228 P0922QS","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/FBM228P0922QS.png?v=1782204728","url":"https:\/\/www.5gplc.com\/products\/fbm228-p0922qs-analog-input-module-foxboro","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}