{"product_id":"fbm219-p0916rh-voltage-monitor-module-foxboro","title":"FBM219 P0916RH Voltage Monitor Module | Foxboro","description":"\u003cp\u003eConfigured for discrete voltage monitoring and signal switching in I\/A Series DCS platforms, the \u003cstrong\u003eFoxboro FBM219 P0916RH\u003c\/strong\u003e (\u003cstrong\u003eFBM219\u003c\/strong\u003e Voltage Monitor Module) provides direct physical execution of 24-input monitoring and 8-output control.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFBM219 P0916RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.5 cm x 10 cm x 4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e24 inputs \/ 8 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFusing\u003c\/td\u003e\n\u003ctd\u003e0.25 A integrated fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003eThe FBM219 module interfaces with field loops to monitor voltage levels and execute discrete output commands. While the primary function involves discrete state monitoring rather than analog loop control, the module maintains channel-to-channel isolation to prevent potential cross-talk between input and output circuits. Integration with HART-capable field instruments is supported through the DCS backplane, where the FBM219 provides the necessary voltage status feedback to the I\/A Series host. Proper implementation of HART communication requires that the module and associated field devices are configured to ensure that signal frequency components are not suppressed by the module's input filtering characteristics.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the FBM219 support hot-swapping under normal operating conditions?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports hot-swapping within the I\/A Series baseplate environment. Users must ensure that the associated I\/O channels are placed in a safe state via the control software to prevent unintended output activation or state changes during module insertion or removal.\u003c\/p\u003e\n\u003cp\u003eQ: How is the integrated 0.25 A fuse managed in the event of an output overcurrent?\u003c\/p\u003e\n\u003cp\u003eA: The 0.25 A fuse provides overcurrent protection for the output circuits. If a fault causes the fuse to open, the module must be removed, and the fuse condition verified. Fuses are typically non-serviceable by the end-user; refer to factory maintenance protocols for module replacement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the module onto the dedicated Modular Baseplate, ensuring the mechanical connectors are fully seated to establish the backplane bus communication link.\u003c\/li\u003e\n\u003cli\u003eTerminate all input and output wiring at the termination assembly (TA), observing the voltage limits of 60 V for monitoring inputs.\u003c\/li\u003e\n\u003cli\u003eVerify that the shield drain wires are terminated to the chassis ground at the cabinet entry point to reduce common-mode noise on the voltage monitor inputs.\u003c\/li\u003e\n\u003cli\u003eConfirm that the module orientation allows for adequate thermal dissipation, as the internal switching circuitry generates heat under full load conditions.\u003c\/li\u003e\n\u003cli\u003ePerform a point-to-point I\/O check using the I\/A Series configuration software to confirm that each of the 24 inputs and 8 outputs responds correctly to field-side stimuli before commissioning the control loop.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":53028026679605,"sku":"FBM219 P0916RH","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/FBM219P0916RH.png?v=1782202392","url":"https:\/\/www.5gplc.com\/products\/fbm219-p0916rh-voltage-monitor-module-foxboro","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}