{"product_id":"fbm214b-p0922vt-foxboro-hart-communication-input-interface-module","title":"FBM214B P0922VT | Foxboro | HART Communication Input Interface Module","description":"\u003cp\u003eConfigured for signal acquisition in I\/A Series control networks, the \u003cstrong\u003eFoxboro FBM214B P0922VT\u003c\/strong\u003e (\u003cstrong\u003eP0922VT\u003c\/strong\u003e HART Communication Input Interface Module) provides direct physical\/electrical execution. This hardware component serves as the primary interface for 8 analog input channels, facilitating the transmission of 4-20 mA current loops and superimposed HART digital FSK signals from field devices to the host controller.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eP0922VT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eManufacturer Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard I\/A Series module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7 W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Count\u003c\/td\u003e\n\u003ctd\u003e8 analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Support\u003c\/td\u003e\n\u003ctd\u003e4-20 mA \/ HART digital FSK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Instrumentation Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe P0922VT maintains high signal integrity within the DCS infrastructure by utilizing effective common-mode and normal-mode rejection techniques. The module provides a common-mode rejection ratio exceeding 100 dB at 50\/60 Hz and a normal-mode rejection ratio of 35 dB, significantly reducing the impact of industrial electromagnetic interference. The architecture allows for the simultaneous processing of analog process variables and HART digital diagnostic data at a rate of 2 messages per second. Consistent channel-to-channel isolation is maintained to prevent cross-talk and ground potential shifts between disparate field loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the FBM214B P0922VT be integrated into redundant controller configurations?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports redundant pairing. In such configurations, the primary and secondary modules synchronize data to maintain continuous process monitoring and HART communications during a single-module failure.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module compatible with standard 24 VDC power supply architectures?\u003c\/p\u003e\n\u003cp\u003eA: The module is designed for a nominal input voltage of 24 VDC with a tolerance of +5 percent to -10 percent. Ensure the power distribution to the termination assembly is within these bounds to prevent erratic performance or power-cycle resets.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the P0922VT onto the I\/A Series modular baseplate, ensuring the connector pins are fully seated and clear of debris.\u003c\/li\u003e\n\u003cli\u003eTerminate 4-20 mA field loops at the associated terminal assembly, utilizing shielded cables to maintain the 35 dB normal-mode rejection performance.\u003c\/li\u003e\n\u003cli\u003eEnsure the shield drain wire is connected to a high-quality earth ground point to protect against electrical noise.\u003c\/li\u003e\n\u003cli\u003eVerify that the loop resistance complies with the module's input requirements before energizing the field instruments.\u003c\/li\u003e\n\u003cli\u003ePerform an initial diagnostic check using the I\/A Series maintenance tools to confirm communication with the HART-enabled field devices post-installation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":53028140908853,"sku":"FBM214B P0922VT","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/FBM214BP0927AH_2d7a37aa-8340-4f0a-8a98-257ae7ffb3bd.png?v=1782204867","url":"https:\/\/www.5gplc.com\/products\/fbm214b-p0922vt-foxboro-hart-communication-input-interface-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}