{"product_id":"f3cu04-1s-fa-m3-temperature-pid-control-module-yokogawa","title":"F3CU04-1S FA-M3 Temperature PID Control Module | Yokogawa","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa F3CU04-1S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a specialized Temperature PID Control module for the FA-M3 controller series. This module automates thermal regulation for critical industrial processes, maintaining setpoints through advanced PID logic. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring precise thermal response and stable alarm monitoring for your factory automation line.\u003c\/p\u003e\n\u003ch3\u003ePart Number Breakdown\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eF3CU04\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBase Model\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTemperature PID Control Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003e-1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard PID hardware configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eS\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRevision\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHardware revision level\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAlarm Outputs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 outputs per loop (2 relays per loop)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eAlarm Functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eON-delay timing included\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWarm-up Time\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 minutes minimum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMax Ambient Change Rate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10°C\/h maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e470 mA (5 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eExternal Connection\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDual 18-point terminal blocks (M3.5 screws)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eShipping Weight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Alarm Logic:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe F3CU04-1S provides 4 alarm outputs per control loop. This granular alarm structure allows engineers to configure primary and secondary safety triggers (e.g., Warning and Shutdown) without requiring external relay logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStable Thermal Performance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module features an \"Alarm ON-delay\" function. This capability filters out transient temperature spikes, preventing nuisance alarms in processes where minor, non-critical fluctuations occur during normal operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRobust Connectivity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module utilizes two 18-point terminal blocks with M3.5 screws. This connection method ensures a high-torque mechanical grip on field wiring, preventing loose connections that often trigger signal drift in precision thermal applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEngineered for stable operation, the F3CU04-1S handles ambient temperature changes up to 10°C\/h without degrading PID control accuracy. This robustness keeps process variables steady, even in plant environments experiencing significant seasonal or daily temperature swings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat does the \"30-minute warm-up\" specification mean for my process?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module requires 30 minutes to stabilize its internal reference voltage and thermal sensor circuitry. Ensure you power on the module at least 30 minutes before enabling the active PID control loops to guarantee maximum accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I replace an older F3CU04 revision with the -1S model?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe F3CU04-1S maintains backward compatibility with standard FA-M3 base units. However, always review your existing control program logic, as updated hardware revisions occasionally include minor register mapping changes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do the two input relays for alarms 1 and 2 operate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEach control loop provides two specific alarm inputs. You define these in the software to trigger based on deviation, absolute value, or rate-of-change, providing flexible safety interlocks for your specific thermal loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the F3CU04-1S susceptible to interference from nearby motor controllers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYokogawa designs the F3CU04-1S with internal signal isolation. However, for maximum precision, route your temperature sensor leads (thermocouple or RTD) away from high-power cabling or AC motor drives to minimize electromagnetic noise pickup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52777480323381,"sku":"F3CU04-1S","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3CU04-1S.png?v=1776916486","url":"https:\/\/www.5gplc.com\/products\/f3cu04-1s-fa-m3-temperature-pid-control-module-yokogawa","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}