{"product_id":"f3ad04-0n-yokogawa-fa-m3-analog-input-module","title":"F3AD04-0N | Yokogawa FA-M3 Analog Input Module","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYokogawa F3AD04-0N\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as a precision Analog Input Module for the FA-M3 Range-free multi-controller series. This module converts continuous voltage signals from field sensors into digital data that the PLC processor can execute. Despite the \"discontinued\" status from the manufacturer in many regions, we provide this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efactory stock, ensuring your legacy machine control systems remain operational without costly redesigns.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eFeature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage (DC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eInput Ranges\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 5 VDC, 1 to 5 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh-speed A\/D Conversion\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries Compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFA-M3 (Yushin\/Yokogawa)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModule Category\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePLC \/ Machine Control\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.30 lbs (Approx. 0.14 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Speed A\/D Processing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe F3AD04-0N utilizes a high-resolution A\/D converter to translate voltage fluctuations into precise digital values. This speed allows the PLC to react to process changes in real-time, maintaining tight control over machine movements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow Power Footprint:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module draws minimal current from the PLC backplane. This efficiency reduces the overall heat signature within the control cabinet, protecting adjacent CPU and I\/O modules from thermal degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Legacy Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis module fits directly into standard FA-M3 base units. It eliminates the need for external signal conditioners when handling standard 0-5V or 1-5V signals, saving rail space and reducing wiring complexity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePlug-and-Play Maintenance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unit features a standard terminal block interface. Maintenance teams replace failed units rapidly by swapping the module and reattaching the pre-wired terminal, minimizing production downtime during repairs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the F3AD04-0N to measure 4-20mA signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe F3AD04-0N natively accepts 1 to 5 VDC voltage signals. To measure a 4-20mA current loop, you must install a high-precision 250-ohm shunt resistor across the input terminals to convert the current into a 1-5V signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I configure the input range for different channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe PLC CPU software or internal DIP switches (depending on the base unit configuration) set the specific range. Always verify the software scaling parameters in the FA-M3 programming environment to ensure the digital values match your field sensor's output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSince the manufacturer discontinued this model, is this unit a refurbished item?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. We explicitly supply\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal stock. These units originate from unused surplus inventories and maintain their original factory integrity, offering a reliable alternative to used or repaired hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat precautions should I take against signal noise?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWe recommend using shielded twisted-pair (STP) cabling for all analog voltage inputs. Connect the shield to the designated ground point on the FA-M3 rack to prevent electromagnetic interference from distorting your A\/D conversion accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":52777039135029,"sku":"F3AD04-0N","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/F3AD04-0N.png?v=1776913774","url":"https:\/\/www.5gplc.com\/products\/f3ad04-0n-yokogawa-fa-m3-analog-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}