{"product_id":"epro-con021-916-200-eddy-current-signal-converter","title":"EPRO CON021\/916-200 Eddy Current Signal Converter","description":"\u003cp\u003eConfigured for high-frequency vibration signal conditioning in turbomachinery monitoring systems, the \u003cstrong\u003eEPRO CON021\/916-200\u003c\/strong\u003e (\u003cstrong\u003eCON021\/916-200\u003c\/strong\u003e) Eddy Current Signal Converter provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON021\/916-200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEPRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard LMgSi 0.5 F22 housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDependent on input voltage -23 VDC to -32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e20.0 mm (Extended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e0 Hz to 20000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e-4 VDC to -20 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eGap Voltage Validation (-10 VDC targets)\u003c\/h3\u003e\n\u003cp\u003eThe CON021\/916-200 utilizes a high-frequency oscillator to drive the PR6426 transducer probe. To ensure accurate linearization over the 20.0 mm measuring range, the system necessitates precise gap voltage validation. The converter centers its output characteristic around a nominal target of -10 VDC, which represents the mid-point of the physical measurement gap. Maintenance of this -10 VDC baseline is mandatory during static commissioning; significant deviations indicate mechanical misalignment, transducer saturation, or degradation of the conductive target surface.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the CON021\/916-200 compatible with standard PR6424 probes?\u003c\/p\u003e\n\u003cp\u003eA: No. This converter is specifically calibrated for the PR6426 extended range transducer. Mismatched probe\/converter pairs will result in non-linear signal response and increased measurement error beyond the 2.5% specification.\u003c\/p\u003e\n\u003cp\u003eQ: What are the installation requirements for the IP20 housing?\u003c\/p\u003e\n\u003cp\u003eA: The IP20 protection class mandates installation within a secondary protective enclosure or control cabinet to prevent exposure to moisture, oil mist, or conductive metallic dust common in turbomachinery environments.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the converter housing using four M5x20 screws onto a rigid, grounded surface to ensure structural integrity and chassis bonding.\u003c\/li\u003e\n\u003cli\u003eTerminate the supply and output wiring using high-quality wire-end sleeves on the screw terminals, ensuring no stray strands exist that could cause short-circuits.\u003c\/li\u003e\n\u003cli\u003eVerify the -23 VDC to -32 VDC power supply polarity before applying voltage, as incorrect polarity will damage the internal oscillator stage.\u003c\/li\u003e\n\u003cli\u003eUtilize shielded, twisted-pair cabling for the output signal, terminating the shield exclusively at the monitoring system (DCS\/TSI) input to prevent ground-loop injection of 50\/60 Hz noise.\u003c\/li\u003e\n\u003cli\u003eInspect the transducer Lemo-plug connection to confirm the self-locking mechanism is fully engaged and free of surface oxidation.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53008985850165,"sku":"CON021\/916-200","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/PR6426010-140_CON011916-1202_52f97fae-188d-4c61-8ac2-c9d1c50349bd.png?v=1781680867","url":"https:\/\/www.5gplc.com\/products\/epro-con021-916-200-eddy-current-signal-converter","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}