{"product_id":"emerson-ve5010-intrinsically-safe-power-supply-carrier","title":"Emerson VE5010 Intrinsically Safe Power Supply Carrier","description":"\u003cp\u003eConfigured for power distribution and signal isolation in DeltaV I\/O subsystems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson VE5010\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eVE5010\u003c\/strong\u003e, also cataloged as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKJ4101X1-BC1\u003c\/strong\u003e) provides direct physical\/electrical execution of intrinsically safe power regulation for hazardous area instrumentation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVE5010\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.82 kg (1.8 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e93 mm x 168 mm x 35 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive distribution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIS Power Supply Carrier\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control: Intrinsic Safety (Ex i) Barriers\u003c\/h3\u003e\n\u003cp\u003eThe VE5010 carrier serves as a foundational component for implementing intrinsic safety within the DeltaV architecture. It facilitates the distribution of power to connected I\/O modules while maintaining stringent energy-limiting barriers that prevent ignition-capable electrical or thermal energy from entering hazardous areas. The carrier is engineered to support Ex i compliance, ensuring that field-side circuits are galvanically isolated from the non-hazardous control bus. This implementation requires meticulous adherence to loop-drawing specifications and cable capacitance\/inductance limits to maintain the safety integrity of the installed field instruments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the VE5010 be used for non-intrinsically safe I\/O modules?\u003c\/p\u003e\n\u003cp\u003eA: The VE5010 is specifically designed for use with intrinsically safe DeltaV I\/O modules. Use with non-IS modules will negate the intended safety protection and may result in improper module operation or damage to the carrier backplane.\u003c\/p\u003e\n\u003cp\u003eQ: What is the recommended mounting configuration?\u003c\/p\u003e\n\u003cp\u003eA: The module supports DIN-rail or panel mounting. Ensure that the mounting surface is grounded and that the module is installed in an environment free from excessive vibration, which could compromise the electrical contact between the module and the carrier backplane pins.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure the carrier to the DIN rail or panel using appropriate fastening hardware. Maintain adequate spacing between the VE5010 and non-IS components to prevent unintended coupling or mechanical interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTerminate 24 VDC input power at the carrier power terminals. All field wiring must be routed according to local hazardous area installation codes, strictly segregating IS and non-IS circuits to prevent cross-talk or short-circuit failures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBond the carrier chassis to the system earth ground. A low-impedance ground path is mandatory to ensure the stability of the safety barriers and to suppress electromagnetic noise that could interfere with signal precision.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVerification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAfter installation, measure the output voltage at the module connection points to ensure proper power delivery. Conduct a continuity test on all field loops to verify isolation from ground and ensure that field device capacitance and inductance parameters conform to the system safety design.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52924383953205,"sku":"VE5010","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/VE4005S2B1_58304b68-ea26-4b10-a417-b2d082d5ca12.png?v=1779784782","url":"https:\/\/www.5gplc.com\/products\/emerson-ve5010-intrinsically-safe-power-supply-carrier","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}