{"product_id":"emerson-ve5008-power-supply-systems","title":"Emerson VE5008 Power Supply Systems","description":"\u003cp\u003eConfigured for high-availability power distribution in DeltaV control networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson VE5008\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eVE5008\u003c\/strong\u003e, also cataloged as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKJ1501X1-BC2\u003c\/strong\u003e) Redundant Power Supply Module provides direct physical\/electrical execution of 24 VDC output regulation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVE5008\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard DeltaV power module form factor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 deg C to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (+\/- 5%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 A (max per channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRedundancy\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1+1 redundant configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control: Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe VE5008 power module ensures system stability through independent rail outputs and rigorous internal channel-to-channel isolation. By maintaining galvanic separation between power output channels, the module prevents a localized short-circuit or fault in one field circuit from causing a total voltage collapse across the entire redundant power bus. The architecture supports a 1+1 redundancy scheme, where dual modules operate in parallel to ensure uninterrupted 24 VDC delivery during a single module failure event. High-frequency filtering and integrated voltage regulation maintain tight output tolerances (24 VDC +\/- 5%), protecting sensitive process control electronics from fluctuations in input AC or DC supply lines.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum load capacity when utilizing the 1+1 redundancy feature?\u003c\/p\u003e\n\u003cp\u003eA: In a 1+1 redundant configuration, the total load capacity remains 8 A per channel, provided by the active\/standby module pair. If the load exceeds the capacity of a single module, the redundancy is effectively nullified as both modules may operate at their current limits.\u003c\/p\u003e\n\u003cp\u003eQ: Is the VE5008 module field-replaceable while the system is powered?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module supports hot-swap operations within the DeltaV power distribution carrier. Ensure that the redundant module is actively carrying the load before extracting the faulty unit to maintain voltage continuity to the I\/O bus.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure the VE5008 module into the DeltaV power carrier. Ensure the module is fully latched and the electrical contacts are firmly seated against the carrier backplane to minimize contact resistance and heat generation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect the 100-240 VAC or 125-375 VDC input supply to the carrier input terminals. Use properly sized, shielded cabling and ensure the input source is protected by a fast-acting circuit breaker sized according to the system load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBond the power carrier chassis to the system common ground bus. This is mandatory to prevent floating voltage potentials and to ensure the effectiveness of internal surge protection circuitry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTesting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAfter installation, verify the output voltage at the carrier terminals using a calibrated multimeter. Confirm the redundancy status via the DeltaV workstation diagnostics to ensure the secondary module is ready for automatic switch-over.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52924286665013,"sku":"VE5008","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/VE5008.png?v=1779780943","url":"https:\/\/www.5gplc.com\/products\/emerson-ve5008-power-supply-systems","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}