{"product_id":"emerson-ve4005s2b2-analog-output-card","title":"Emerson VE4005S2B2 Analog Output Card","description":"\u003cp\u003eConfigured for precision process control in DeltaV automation networks, the \u003cstrong\u003eEmerson VE4005S2B2\u003c\/strong\u003e (\u003cstrong\u003eVE4005S2B2\u003c\/strong\u003e Analog Output Card) provides direct physical\/electrical execution of 8-channel 4-20 mA HART standard analog output signals.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVE4005S2B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DeltaV I\/O module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control: 4-20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003eThe VE4005S2B2 supports the industry-standard HART (Highway Addressable Remote Transducer) protocol, enabling bi-directional digital communication over the primary 4-20 mA analog control signal. This functionality facilitates the transmission of secondary device variables, diagnostic status, and configuration parameters without requiring additional field wiring. The output architecture ensures that HART modulated signals are superimposed on the analog current loop, maintaining compatibility with standard HART-compliant field actuators and positioners. This integrated protocol handling allows for real-time monitoring of actuator health and process loop performance within the DeltaV environment.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Is this card compatible with non-HART field actuators?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The VE4005S2B2 provides a standard 4-20 mA output that is backward compatible with non-HART analog actuators. When no HART communication is detected on the loop, the module functions as a conventional analog output.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module be hot-swapped while the process is active?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The VE4005S2B2 supports hot-swap operations within a powered DeltaV I\/O carrier. Ensure the control strategy is appropriately configured or placed in maintenance mode before removing the module to avoid inadvertent process upsets during physical extraction.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Insert the module into the designated slot on the DeltaV I\/O carrier. Verify that the mechanical latch is fully engaged and the backplane connector is seated to ensure electrical continuity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Utilize the standard HART I\/O termination block for field wiring. Ensure that the loop resistance is within the allowable range specified for the 4-20 mA output to maintain signal accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Terminate cable shields at the cabinet ground bus. Proper shielding is required to prevent electromagnetic interference from distorting the HART digital carrier frequency overlaid on the 4-20 mA analog signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification:\u003c\/strong\u003e Perform a loop diagnostic test via the DeltaV engineering workstation to confirm that the output current matches the commanded values and that HART communication is established with the field device.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52924533145909,"sku":"VE4005S2B2","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/KJ3102X1-BA1_1b9b1e37-3925-4715-95e0-55ce860eb515.png?v=1779789651","url":"https:\/\/www.5gplc.com\/products\/emerson-ve4005s2b2-analog-output-card","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}