{"product_id":"emerson-ve4005s2b1-m-series-analog-output-termination-block","title":"Emerson VE4005S2B1 M-Series Analog Output Termination Block","description":"\u003cp\u003eConfigured for analog signal output in DeltaV I\/O subsystems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson VE4005S2B1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eVE4005S2B1\u003c\/strong\u003e) Analog Output Termination Block provides direct physical\/electrical execution of 8-channel 4-20 mA control signal distribution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVE4005S2B1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard M-series block footprint\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive distribution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannel Count\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control: Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe VE4005S2B1 termination block facilitates signal distribution while maintaining channel-to-channel isolation on the DeltaV I\/O carrier. This structural isolation prevents ground loops and electrical interference from propagating between parallel output loops. By physically separating the 4-20 mA signal paths, the block ensures that transient voltages or fault conditions in one actuator circuit do not affect the control signal integrity of adjacent channels. This design maintains the electrical performance of the analog output card, ensuring deterministic loop current regulation across all 8 channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does this termination block support field-side loop power?\u003c\/p\u003e\n\u003cp\u003eA: The VE4005S2B1 is a passive termination component designed to route signals from the analog output card to the field devices. Any required loop power must be provided by the system power supply via the I\/O carrier backplane or external sources, depending on the specific loop configuration.\u003c\/p\u003e\n\u003cp\u003eQ: Is this block hot-swappable during system operation?\u003c\/p\u003e\n\u003cp\u003eA: The VE4005S2B1 is designed for use on DeltaV M-series carriers that support hot-swapping. However, ensure that the corresponding analog output channel is placed in a safe state or manual control mode within the DeltaV software before physical removal to prevent uncontrolled actuator movement.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSnap the termination block onto the M-series I\/O carrier. Ensure the mechanical keying pins align correctly to verify that the block is locked into the intended slot position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse shielded twisted pair cabling for all 4-20 mA loops to minimize electromagnetic interference. Terminate cable shields at the designated ground lug on the carrier to ensure a low-impedance reference to the cabinet ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTightening:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTighten all terminal screws to the specified torque. Avoid over-torquing, which may cause mechanical damage to the terminal block's internal contact plates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVerification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePrior to commissioning, verify loop continuity and polarity. Confirm that the 4-20 mA output current matches the commanded values from the controller by measuring the current in series with the field loop.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52924264907061,"sku":"VE4005S2B1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/VE4005S2B1.png?v=1779780371","url":"https:\/\/www.5gplc.com\/products\/emerson-ve4005s2b1-m-series-analog-output-termination-block","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}