{"product_id":"emerson-ve4003s2b2-deltav-m-series-analog-input-termination-block","title":"Emerson VE4003S2B2 DeltaV M-Series Analog Input Termination Block","description":"\u003cp\u003eConfigured for analog signal acquisition in DeltaV I\/O subsystems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson VE4003S2B2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eVE4003S2B2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFused I\/O Termination Block) provides direct physical\/electrical execution of 4-20 mA HART signal monitoring.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVE4003S2B2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.73 kg (1.60 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard M-series termination block\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive field power distribution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannel Count\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 channels\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4-20 mA HART\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control: 4-20 mA HART Loop Protocol\u003c\/h3\u003e\n\u003cp\u003eThe VE4003S2B2 block supports the 4-20 mA HART loop protocol, enabling digital communication overlay for transmitter diagnostics and configuration. The module is architected for both 2-wire and 4-wire transmitter configurations, selectable via jumper or terminal wiring. Internal circuitry maintains channel-to-channel isolation, preventing signal interference between individual loops. The block operates within a 12-24 VDC range to provide field loop power, ensuring compliant transmission of both the analog process variable and the frequency-shift keying (FSK) digital HART data to the DeltaV I\/O card.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can this termination block be configured for different transmitter wiring types?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The VE4003S2B2 supports both 2-wire and 4-wire transmitter connections. Ensure the field wiring matches the selected input configuration to prevent loop power supply damage or signal clipping.\u003c\/p\u003e\n\u003cp\u003eQ: What is the purpose of the \"Key Positions A 1\" designation?\u003c\/p\u003e\n\u003cp\u003eA: This is a mechanical keying setting specific to the M-series carrier. It prevents the installation of incorrect I\/O card types into this terminal block, ensuring that high-voltage or incompatible signal types are not inadvertently connected to the analog input circuitry.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSeat the termination block onto the M-series carrier. Verify that the keying pins are set to position A 1 as required by the I\/O card configuration to permit proper latching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUse shielded twisted pair cables for all analog signal runs. Ground the shield at the cabinet entry point using an approved grounding bar to minimize electromagnetic interference on the 4-20 mA loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTermination:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure all terminal screws are tightened to the specified torque. High-resistance connections can introduce voltage drops that affect the accuracy of the 4-20 mA measurement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVerification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCheck for correct loop voltage (12-24 VDC) at the terminals prior to connecting the field instrument. If HART communication is intermittent, verify that the load resistance on the loop falls within the required specifications for FSK signal transmission.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52924147532085,"sku":"VE4003S2B2","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/VE4002S1T2B6_97243936-ab2e-493f-998b-2708115b5ce0.png?v=1779777504","url":"https:\/\/www.5gplc.com\/products\/emerson-ve4003s2b2-deltav-m-series-analog-input-termination-block","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}