{"product_id":"emerson-pr6424-000-130-con021-eddy-current-sensor","title":"Emerson PR6424\/000-130 CON021 Eddy Current Sensor","description":"\u003cp\u003eConfigured for non-contact displacement measurement in rotating machinery networks, the \u003cstrong\u003eEmerson PR6424\/000-130 CON021\u003c\/strong\u003e (\u003cstrong\u003ePR6424\u003c\/strong\u003e Eddy Current Sensor) provides direct physical execution of radial and axial dynamic shaft displacement sensing.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6424\/000-130 CON021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e160 mm x 160 mm x 40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (Powered via CON021)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd\u003e16 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Integration\u003c\/h3\u003e\n\u003cp\u003eThe PR6424 sensor utilizes electromagnetic induction to detect distance relative to a metallic surface. Precise rotor dynamics analysis is dependent on correct eddy-current probe scaling to ensure the transducer voltage output corresponds linearly to shaft movement. During installation, users must verify gap voltage validation to maintain a -10 VDC center-point target, which ensures the sensor remains within its operational linearity. Furthermore, to eliminate measurement errors, the system requires effective cross-talk suppression by ensuring that the high-frequency coaxial cables are routed separately from external noise sources, thereby preventing interference with the dynamic waveform capture of eccentricity and shaft position.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the PR6424 sensor be used with cable lengths other than the factory-specified configuration?\u003c\/p\u003e\n\u003cp\u003eA: No. The PR6424 and the CON021 signal conditioner are a factory-calibrated system. Modifying cable length will alter system impedance and resonant frequency, which corrupts the displacement measurement accuracy.\u003c\/p\u003e\n\u003cp\u003eQ: Is the probe tip sensitive to mounting torque during installation?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Excessive torque on the probe body can lead to physical deformation of the sensor or cracking of the ceramic tip. Use only the minimum torque required to secure the sensor assembly firmly in the mounting bracket.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Gap Setting\u003c\/strong\u003e: Set the initial distance between the probe tip and the shaft using a calibrated feeler gauge. Target the center of the total linear range to allow for full shaft excursion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Stability\u003c\/strong\u003e: Install the probe in a vibration-free, rigid bracket. If the mounting bracket flexes or vibrates, the sensor will erroneously register this motion as shaft vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Cabling\u003c\/strong\u003e: Route the coaxial cable through shielded conduits. Keep the cable runs as short as possible to avoid pick-up of electromagnetic interference (EMI) that can skew the high-frequency dynamic signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Integrity\u003c\/strong\u003e: Inspect all coaxial connectors for environmental contamination. Ensure the interface between the PR6424 and the CON021 is clean, as oxidation at this junction causes signal attenuation and intermittent gap voltage drift.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53011125666101,"sku":"CON021+PR6424\/000-130","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON021_PR6424000-130.png?v=1781761514","url":"https:\/\/www.5gplc.com\/products\/emerson-pr6424-000-130-con021-eddy-current-sensor","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}