{"product_id":"emerson-ovation-1c31122g02-digital-output-module","title":"Emerson Ovation 1C31122G02 Digital Output Module","description":"\u003cp\u003eConfigured for discrete signal execution in Ovation control platforms, the \u003cstrong\u003eEmerson 1C31122G02\u003c\/strong\u003e (\u003cstrong\u003e1C31122G02\u003c\/strong\u003e) provides direct physical and electrical execution of 16-channel digital output commands. The module operates as a dedicated hardware component for driving field-side loads across a wide voltage range, ensuring deterministic response timing for process actuation and status signaling within the control network.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1C31122G02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e128 mm x 80 mm x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem backplane nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Density\u003c\/td\u003e\n\u003ctd\u003e16 Channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e5-60 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe 1C31122G02 utilizes robust backplane bus communication to maintain synchronization with the Ovation controller's scan cycles. By implementing channel-to-channel isolation, the module prevents transient voltage surges from propagating across the output bus, ensuring that individual load failures do not compromise the integrity of adjacent control channels. The circuitry supports broad voltage compatibility, allowing for flexible integration with various field-side solenoid, relay, and indicator requirements while maintaining precise duty cycle performance.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support hot-swapping under load?\u003c\/p\u003e\n\u003cp\u003eA: The module is designed for hot-swapping within an energized Ovation backplane. However, users should ensure the corresponding software logic is in a safe state to prevent unintended actuation of field devices during the module extraction or insertion process.\u003c\/p\u003e\n\u003cp\u003eQ: How is the output state maintained during a control system communication loss?\u003c\/p\u003e\n\u003cp\u003eA: In the event of a backplane communication failure, the module is designed to transition outputs to a pre-configured fail-safe state (either de-energized or held, depending on the system configuration) to ensure process safety.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Seat the module securely into the designated I\/O rack slot. Ensure that the backplane connector is fully engaged and the front retaining latches are locked to provide mechanical stability against cabinet vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: Bond the cabinet chassis to the system earth ground. Ensure the output common is referenced appropriately to the return path of the field-side load power supply to prevent ground potential differences.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring\u003c\/strong\u003e: Use twisted-pair, shielded cabling for all field output wiring. Route these conductors in dedicated wireways, maintaining adequate physical separation from high-voltage AC lines to mitigate inductive noise coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification\u003c\/strong\u003e: Prior to system energization, verify loop continuity and polarity for each output channel. Perform a digital output test sequence via the Ovation engineering workstation to confirm that each channel triggers the intended field device as commanded.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52934391988533,"sku":"1C31122G02","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1C31122G02.png?v=1779960299","url":"https:\/\/www.5gplc.com\/products\/emerson-ovation-1c31122g02-digital-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}