{"product_id":"emerson-kl3102x1-ba1-analog-output-charm-module","title":"Emerson KL3102X1-BA1 Analog Output CHARM Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\n\u003cp\u003eConfigured for Specific Technical Task in System\/Network Name, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson KL3102X1-BA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eKL3102X1-BA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAnalog Output Module) provides direct physical\/electrical execution. The hardware functions as an Intrinsically Safe (I.S.) electronic component interfacing backplane infrastructure with field devices to regulate current or voltage signals. It executes control loop commands through galvanic energy limitation to ensure safety in hazardous locations.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKL3102X1-BA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.08 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e114 mm x 22 mm x 42 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.34 W maximum (56 mA at 24 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCHARM Bus Power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+6.3 VDC at 0 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eField Circuit Power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+24 VDC at 56 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShock Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10g, 11 ms half-sine wave\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVibration Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 mm peak-to-peak (2-13.2 Hz); 0.7g (13.2-150 Hz)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHumidity Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95%, non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAirborne Contaminant Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eISA-S71.04 Class G3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eKey Position\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates dedicated hardware to manage 4-20 mA HART loop protocol signaling over field circuits. Internal galvanic isolation barriers provide complete channel-to-channel isolation, preventing ground loops and protecting backplane electronics from field-side electrical surges. The digital HART carrier signal is modulated onto the analog output current without disrupting the primary analog variables, allowing bi-directional digital data transfer between asset management software and field instruments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support hot-swap replacement during live operation?\u003c\/p\u003e\n\u003cp\u003eA: No, hot-swap capability is not supported by this specific module. Power to the field circuit and backplane carrier must be completely isolated and turned off prior to physical removal or installation of the hardware to prevent damage to the components.\u003c\/p\u003e\n\u003cp\u003eQ: Is field-side calibration required upon initial commissioning?\u003c\/p\u003e\n\u003cp\u003eA: No, the hardware is fully factory calibrated. No field calibration mechanisms or adjustment potentiometers are present on the unit, and none are necessary throughout its standard operational lifespan.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Alignment\u003c\/strong\u003e: Verify the mechanical carrier block key is configured to Position C2 prior to insertion. Align the module pins with the carrier slot and press firmly until the retaining clips engage securely.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring and Grounding\u003c\/strong\u003e: Route all intrinsically safe field wiring in separate conduits or wire ducts isolated from non-intrinsically safe cabling to prevent induction and maintain loop integrity. Ensure the shield wire is grounded at a single point according to standard industrial instrumentation practices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Enforcement\u003c\/strong\u003e: Ensure the installation enclosure provides adequate ingress protection and heat dissipation to maintain ambient air temperatures within the rated -40 to +70 deg C range. Keep within the 5% to 95% non-condensing relative humidity parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52921367003445,"sku":"KL3102X1-BA1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/KL3101X1-BA1__1_57592873-c07b-481f-b808-dc77392c8355.png?v=1779674173","url":"https:\/\/www.5gplc.com\/products\/emerson-kl3102x1-ba1-analog-output-charm-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}