{"product_id":"emerson-kl2001x1-ba1-charms-smart-logic-solver","title":"Emerson KL2001X1-BA1 CHARMs Smart Logic Solver","description":"\u003cp\u003eConfigured for high-density safety logic execution in DeltaV distributed control topologies, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson KL2001X1-BA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eKL2001X1-BA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCHARMs Smart Logic Solver) provides direct physical\/electrical execution. This localized processing subassembly scans electronic signal registers across localized Characterization Modules (CHARMs), executing programmed safety interlock equations over a dedicated backplane infrastructure to command active field elements.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKL2001X1-BA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.55 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard CHARMs smart logic solver base footprint\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 deg C to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+24 VDC at 325 mA input power\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLogic Capacity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLocalized safety logic matrix execution\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShock Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10g 1\/2 sine wave for 11 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVibration Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 mm peak-to-peak from 2 to 13.2 Hz; 0.7g from 13.2 to 150 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAirborne Contaminants\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eISA-S71.04-1985 Class G3 compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eChannel-to-Channel Isolation Matrix\u003c\/h3\u003e\n\u003cp\u003eMechanical execution of this electronic safety solver utilizes specialized internal circuitry layers to govern real-time scanning cycles. The component structure implements comprehensive channel-to-channel isolation matrices across the mapped peripheral IO links, protecting inner processing registers from outside voltage drops. This electronic design blocks field loop interference and limits signal degradation across active 4-20 mA HART loop protocol lines linked to the architecture baseplate.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this smart logic solver hardware support continuous hot-swap procedures during active operations?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The subassembly is engineered for redundant hot-swap operations, allowing single hardware card extraction and replacement while the redundant partner card handles online safety logic execution without adding transition processing delay.\u003c\/p\u003e\n\u003cp\u003eQ: What defines the functional response of the module under an input power loss event?\u003c\/p\u003e\n\u003cp\u003eA: Internal hardware tracks monitor the raw +24 VDC input power constantly. If line supply indicators fall past preset execution thresholds, the card triggers an immediate fail-safe state register shift before logic memory shuts down.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBaseplate Track Alignment\u003c\/strong\u003e: Align the solver rear-pin terminal configuration squarely with the target slot rails on the horizontal CHARMs carrier base. Press straight down until the structural retention clips lock tightly over the chassis studs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaster Shield Termination\u003c\/strong\u003e: Route all continuous transmitter cable shields directly into the cabinet master grounding bar network. Implementing single-point grounding methods prevents low-frequency noise from inducing measurement skew across active loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSupply Cable Crimp Parameters\u003c\/strong\u003e: Insert all +24 VDC power supply lines completely into the screw-clamp plug sleeves. Tighten connections to factory specifications to eliminate localized contact resistance anomalies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCorrosive Site Enclosure Control\u003c\/strong\u003e: For field installations tracking high ambient chemical concentrations, locate the chassis inside a sealed positive-pressure industrial cabinet to ensure ongoing operation within Class G3 parameters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52922075414837,"sku":"KL2001X1-BA1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/KL2001X1-BA12.png?v=1779699731","url":"https:\/\/www.5gplc.com\/products\/emerson-kl2001x1-ba1-charms-smart-logic-solver","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}