{"product_id":"emerson-kj4006x1-bt1-deltav-redundant-analog-output-terminal-block","title":"Emerson KJ4006X1-BT1 DeltaV Redundant Analog Output Terminal Block","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson KJ4006X1-BT1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKJ4006X1-BT1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRedundant Analog Output Terminal Block utilized to execute discrete field loop wiring distribution across DeltaV processing nodes. This 8-channel physical connection component mounts directly to system interface carriers, channeling parallel continuous current loop signals from dual redundant processing cards out to electrical field elements without breaking signal synchronization.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKJ4006X1-BT1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.15 kg (0.33 lb)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e48 mm x 130 mm x 41 mm (1.89 in x 5.12 in x 1.61 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 deg C to +70 deg C (-40 deg F to +158 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 deg C to +85 deg C (-40 deg F to +185 deg F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive distribution unit (Rated for localized current loop limits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannel Density\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 analog output paths, redundant topology\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShock Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10g 1\/2 sine wave for 11 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVibration Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 mm peak-to-peak from 2 to 13.2 Hz; 0.7g from 13.2 to 150 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAirborne Contaminants\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eISA-S71.04-1985 Class G3 compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHazardous Location Certification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClass I, Division 2, Groups A, B, C, D\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eChannel-to-Channel Isolation Parameters\u003c\/h3\u003e\n\u003cp\u003eMechanical execution of this passive terminal assembly relies on permanent trace routing layouts to preserve analog driving accuracy. The architecture incorporates channel-to-channel isolation parameters to separate the 8 individual loop connections, stopping transient electrical spikes or field ground loop currents from destabilizing adjoining pathways. This layout shields the primary loop instrumentation from data degradation, supporting uniform execution of the 4-20 mA HART loop protocol layer across both active and standby operational channels simultaneously.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this redundant analog terminal block allow hot-swap maintenance under live bus power?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The structural design of the terminal block enables matching redundant active or standby I\/O modules to undergo online hot-swap insertion and extraction procedures without disrupting current loops or disconnecting any physical field wires.\u003c\/p\u003e\n\u003cp\u003eQ: How is physical hardware keying configured on this terminal block assembly?\u003c\/p\u003e\n\u003cp\u003eA: Mechanical keying positions match automatically based on the specific I\/O module type plugged into the system interface carrier, eliminating the risk of mismatched hardware insertion.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBaseplate Track Mounting\u003c\/strong\u003e: Align the rear locking tabs of the terminal block squarely over the matching DeltaV carrier slot guides. Push the chassis downward until the mechanical fasteners click completely into a locked position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Connection Procedures\u003c\/strong\u003e: Strip field wiring cables according to specified depth parameters, slide the raw copper runs completely into the terminal block wire clamps, and torque all connections uniformly to check for low contact resistance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Line Termination\u003c\/strong\u003e: Route and terminate all analog signal cable shields at the dedicated marshalling cabinet ground bus bar. Implementing a single-point grounding matrix stops low-frequency circulating loops from distorting 4-20 mA telemetry signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Sealing Controls\u003c\/strong\u003e: When installing the block in areas containing Class G3 airborne contaminants, house the assembly inside an enclosed positive-pressure cabinet, tracking that relative humidity stays within the 5% to 95% non-condensing window.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52921874284853,"sku":"KJ4006X1-BT1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/KJ4006X1-BT1.png?v=1779696222","url":"https:\/\/www.5gplc.com\/products\/emerson-kj4006x1-bt1-deltav-redundant-analog-output-terminal-block","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}