{"product_id":"emerson-kj3208x1-bk1-deltav-8-channel-24-vdc-isolated-card","title":"Emerson KJ3208X1-BK1 DeltaV 8-Channel 24 VDC Isolated Card","description":"\u003cp\u003eConfigured for high-density discrete signal isolation in DeltaV distributed control networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson KJ3208X1-BK1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eKJ3208X1-BK1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8-Channel 24 VDC Isolated Card) provides direct physical\/electrical execution. This carrier-mounted interface card isolates, conditions, and maps incoming binary field signals onto the synchronization backplane paths, establishing continuous digital status registers accessible by central processing nodes.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKJ3208X1-BK1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.30 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard S-Series module carrier plug-in profile\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 deg C to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 VDC at 150 mA (Local Bus Power)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eField Circuit Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60 VDC at 1 A per channel maximum\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannel Density\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 channels, fully isolated matrix\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShock Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10g 1\/2 sine wave for 11 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVibration Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 mm peak-to-peak from 2 to 13.2 Hz; 0.7g from 13.2 to 150 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAirborne Contaminants\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eISA-S71.04-1985 Class G3 compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eChannel-to-Channel Isolation Performance\u003c\/h3\u003e\n\u003cp\u003eMechanical execution of this 8-channel hardware module relies on localized physical circuit layer boundaries to safeguard processing logic arrays. The card integrates dedicated optocoupler tracking channels that realize channel-to-channel isolation parameters. This interface barrier blocks electrical cross-talk, grounding offsets, and accidental high-voltage transients on any single 24 VDC loop from compromising neighboring processing lines or introducing noise signals into the parallel 4-20 mA HART loop protocol traces on adjacent slots.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this isolated interface card support continuous hot-swap operation while the local carrier bus is energized?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The hardware includes localized power-limiting contacts that allow online hot-swap installation and removal. Neighboring active channels undergo zero transmission delay or logic state disruptions during an extraction sequence.\u003c\/p\u003e\n\u003cp\u003eQ: What defines the physical threshold of the 60 VDC channel rating under continuous load conditions?\u003c\/p\u003e\n\u003cp\u003eA: The 60 VDC specification dictates the absolute continuous peak voltage allowed across the inductive field circuits without triggering a dielectric breakdown of the internal channel-to-channel isolation barrier.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCarrier Track Engagement\u003c\/strong\u003e: Align the terminal block interface keys with the targeted carrier slot tracks. Apply constant pressure perpendicular to the baseplate assembly until the integrated locking mechanism locks completely.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Continuity Management\u003c\/strong\u003e: Terminate all discrete field wiring shields exclusively at the central marshalling cabinet common grounding bar. Proper single-point grounding layout boundaries block circulating currents from introducing measurement offset harmonics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eField Conductor Torque Limits\u003c\/strong\u003e: Ensure all wires are stripped back according to technical drawings, inserted fully into the terminal clamps, and torqued down to standard engineering values to eliminate contact resistance anomalies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCorrosive Site Protection\u003c\/strong\u003e: In installations containing Class G3 airborne contaminants, mount the hardware inside an airtight positive-pressure enclosure to keep relative humidity parameters within the specified non-condensing windows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52921970360629,"sku":"KJ3208X1-BK1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/KJ3241X1-BK1_04183d5f-f3d1-4d8a-9327-6b3e9a824721.png?v=1779697885","url":"https:\/\/www.5gplc.com\/products\/emerson-kj3208x1-bk1-deltav-8-channel-24-vdc-isolated-card","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}