{"product_id":"emerson-kj3204x1-bk1-deltav-digital-output-module","title":"Emerson KJ3204X1-BK1 DeltaV Digital Output Module","description":"\u003cp\u003eConfigured for high-density discrete output signal processing in DeltaV electronic marshalling subsystems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson KJ3204X1-BK1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eKJ3204X1-BK1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital Output Module) provides direct physical\/electrical execution. This 32-channel hardware component drives low-energy field infrastructure located within hazardous environments via high-side electronic switching, regulating electrical load actuation circuits while maintaining absolute isolation constraints across the local distributed backplane bus.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKJ3204X1-BK1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.20 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard CHARM module profile specification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 deg C to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 VDC at 150 mA (Local Bus Power)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBussed Field Power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC at 3.2 A per card\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eField Circuit Power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC at 100 mA per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannel Density\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 channels (High-Side switching)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShock Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10g 1\/2 sine wave for 11 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVibration Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 mm peak-to-peak from 2 to 13.2 Hz; 0.7g from 13.2 to 150 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAirborne Contaminants\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClass G3 compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAgency Approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATEX certified for hazardous environments\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eChannel-To-Channel Isolation and Process Loop Performance\u003c\/h3\u003e\n\u003cp\u003eMechanical execution of this terminal-mounted high-side sourcing module relies on galvanic separation barriers to maintain continuous process loop signal integrity. The hardware architecture incorporates absolute channel-to-channel isolation parameters, checking that ground faults, field wiring short circuits, or transient electrical surges across an active 24 VDC discrete output track cannot propagate to neighboring hardware slots. Internal logic components utilize this electrical boundary to completely isolate the master controller communication framework from field circuit fluctuations, enabling deterministic execution of parallel digital output paths without cross-talk hazards.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this 32-channel digital output module support live hot-swap procedures while under bus power?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The hardware configuration is engineered for real-time hot-swap insertion and removal within an energized DeltaV carrier block. Internal power sequencing limits initial line inrush currents, preventing diagnostic loop drops or backplane communications interference on neighboring active module slots.\u003c\/p\u003e\n\u003cp\u003eQ: How is the 3.2 A bussed field power consumption distributed across the module channels?\u003c\/p\u003e\n\u003cp\u003eA: The bussed field circuit allocates a maximum capacity of 3.2 A total per card, which allows the concurrent operation of all 32 high-side channels when limited to the factory specified parameters of 100 mA per channel under continuous thermal load.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBaseplate Carrier Insertion\u003c\/strong\u003e: Align the rear terminal guides of the high-side module perpendicularly with the designated slot receptor on the carrier assembly. Press downward firmly until the integrated mechanical retention latches click into place to ensure uniform electrical tracking.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Environment Separation\u003c\/strong\u003e: All 24 VDC output loop cabling routed into hazardous areas must comply with ATEX certification guidelines. Maintain a strict 50 mm physical separation between intrinsically safe field paths and standard non-intrinsically safe power infrastructure inside the enclosure tracks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Ground Maintenance\u003c\/strong\u003e: Terminate all external instrument cable shields exclusively at the main cabinet grounding bar assembly. Implementing a single-point grounding layout prevents low-frequency circulating currents or inductive noise from corrupting discrete output switching logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Control Parameters\u003c\/strong\u003e: For installation sites containing Class G3 airborne contaminants, the marshalling enclosure must maintain a continuous positive-pressure air flow and keep relative humidity below the 95% non-condensing limit to protect active terminal contacts from chemical degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52921796460853,"sku":"KJ3204X1-BK1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/KJ3241X1-BK1_0d673f44-7c37-4f0d-a181-3b197e9a42da.png?v=1779693095","url":"https:\/\/www.5gplc.com\/products\/emerson-kj3204x1-bk1-deltav-digital-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}