{"product_id":"emerson-kj2231x1-ea1-sis-relay-module","title":"Emerson KJ2231X1-EA1 SIS Relay Module","description":"\u003cp\u003eConfigured for safety-instrumented system (SIS) output switching in DeltaV platforms, the \u003cstrong\u003eEmerson KJ2231X1-EA1\u003c\/strong\u003e (\u003cstrong\u003eKJ2231X1-EA1\u003c\/strong\u003e) provides direct physical\/electrical execution of discrete relay control.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ2231X1-EA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.6 cm x 22.9 cm x 5.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 70 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Rating\u003c\/td\u003e\n\u003ctd\u003e30 VDC, 2.5 A \/ 250 VAC, 2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSafety Instrumentation and SIS Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eKJ2231X1-EA1\u003c\/strong\u003e supports high-integrity safety functions through dedicated galvanic isolation circuitry, which prevents ground faults in field-side wiring from affecting the logic solver backplane. In alignment with SIS requirements, this module is capable of fail-safe state execution; upon loss of power or command signal, the relay contacts transition to a pre-defined safe state to ensure process stability. The module architecture facilitates implementation in systems requiring SIL3 certification when integrated with appropriate redundant logic solvers in a 2oo3 architecture, ensuring continuous safety coverage even during single-point module failure.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support hot-swap capabilities in a SIS rack?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports hot-swap functionality. When performing an insertion or removal, ensure the control logic solver is programmed to recognize the module transition and that the associated field output state is effectively bypassed or handled by redundant modules to maintain safety integrity.\u003c\/p\u003e\n\u003cp\u003eQ: Are the relay contacts suitable for high-load inductive switching?\u003c\/p\u003e\n\u003cp\u003eA: The relay contacts are rated for 30 VDC at 2.5 A and 250 VAC at 2.5 A. For inductive loads, implement external arc suppression (e.g., snubbers or flyback diodes) to protect the relay contacts from pitting and material transfer during contact opening.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Secure the module into the designated DeltaV SIS I\/O carrier. Ensure the module locking mechanism is fully engaged to provide stable mechanical mounting and reliable backplane bus connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring\u003c\/strong\u003e: Connect field devices to the module terminal blocks using appropriate gauge wire for the 2.5 A current capacity. Ensure all connections are torqued to manufacturer specifications to prevent high-resistance contact points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: Terminate cable shields at the designated ground bar on the carrier to mitigate electromagnetic interference and ensure proper common-mode noise rejection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVerification\u003c\/strong\u003e: Perform a loop verification test to confirm that relay contact closure corresponds to the command signal from the logic solver and that no unintended impedance is introduced into the SIS output loop.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52933797052725,"sku":"KJ2231X1-EA1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/KJ2231X1-EA1.png?v=1779949761","url":"https:\/\/www.5gplc.com\/products\/emerson-kj2231x1-ea1-sis-relay-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}