{"product_id":"emerson-kj2005x1-sq1-local-bus-power-supply","title":"Emerson KJ2005X1-SQ1 Local Bus Power Supply","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson KJ2005X1-SQ1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eKJ2005X1-SQ1\u003c\/strong\u003e) Local Bus Power Supply operates as a dedicated hardware component for +5 VDC backplane power regulation within DeltaV control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKJ2005X1-SQ1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard DeltaV module form factor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 deg C to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+5 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.4 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control: Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe KJ2005X1-SQ1 power module maintains galvanic isolation between the input power source and the internal logic supply rails. This architecture prevents common-mode noise propagation from the primary power distribution network to the controller backplane, ensuring stable logic operation. The module utilizes internal filtering stages to suppress electrical ripples and transients, thereby maintaining deterministic performance of the local bus communication. This electrical separation is mandatory to protect the backplane electronics from localized fault conditions on the input power segment.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary function of this module in the DeltaV backplane?\u003c\/p\u003e\n\u003cp\u003eA: The KJ2005X1-SQ1 converts input power to a regulated +5 VDC output at 1.4 A to serve as the local bus supply for controller and I\/O modules.\u003c\/p\u003e\n\u003cp\u003eQ: Are there specific installation requirements regarding the airborne contaminants rating?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module is rated for ISA-S71.04-1985 Class G3 environments. Installations in high-corrosion zones must ensure the cabinet maintains adequate sealing to satisfy this rating, as excessive moisture or conductive dust will compromise the conformal coating and module longevity.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInsert the module into the designated power slot on the DeltaV carrier. Verify the locking mechanism is engaged to ensure a low-impedance electrical contact with the backplane pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure the carrier assembly to the cabinet earth ground bus. This is mandatory to maintain the electrical reference necessary for internal surge protection and shielding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConnect the input power leads following established DeltaV power distribution guidelines. Avoid routing power supply wiring adjacent to low-level analog signal lines to prevent inductive noise injection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVerification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAfter installation, measure the output voltage at the backplane test points to confirm +5 VDC regulation before mounting field I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52924321235253,"sku":"KJ2005X1-SQ1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/KJ3241X1-BK1_61ec38e9-a188-4f6a-a141-752638679dd3.png?v=1779781994","url":"https:\/\/www.5gplc.com\/products\/emerson-kj2005x1-sq1-local-bus-power-supply","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}