{"product_id":"emerson-kj1501x1-bk1-deltav-system-power-supply","title":"Emerson KJ1501X1-BK1 DeltaV System Power Supply","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson KJ1501X1-BK1\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eKJ1501X1-BK1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSystem DC Power Supply, operates as a dedicated hardware component for localized voltage regulation within DeltaV S-Series controller subsystems. This unit accepts bulk direct current distribution inputs and transforms them into stable, segmented multi-rail outputs required to energize backplane processing logic and interface circuits across the local area platform.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKJ1501X1-BK1 (Compatible with KJ1501X1-BK2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.45 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard S-Series power module footprint slot width\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 deg C to +60 deg C (extended operational up to +70 deg C)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC at 4.5 A (Input Rating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Rails\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.1 VDC at 2.0 A, 3.4 VDC at 2.0 A, 12 VDC at 8.0 A, 12 VDC at 6.0 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCombined Output Power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.2 W maximum combined from +5.1 VDC and +3.4 VDC rails\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShock Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10g 1\/2 sine wave for 11 ms\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVibration Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 mm peak-to-peak from 2 to 13.2 Hz; 0.7g from 13.2 to 150 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAirborne Contaminants\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eISA-S71.04-1985 Class G3 compliance\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eChannel-To-Channel Isolation and DCS Synchronization\u003c\/h3\u003e\n\u003cp\u003eMechanical execution of this S-Series hardware configuration relies on distinct physical layer design principles to ensure uncompromised loop performance. The internal architecture utilizes continuous channel-to-channel isolation techniques on the secondary side to keep output regulation paths independent. This galvanic segregation limits low-frequency noise coupling and prevents input line fluctuations from affecting the backplane communication rails. It maintains synchronization across parallel operational modules without inducing voltage sag or cross-talk across the 24 VDC field circuit loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this power supply module support online hot-swap exchange when the carrier backplane is energized?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The hardware configuration enables real-time hot-swap procedures while active. Internal power sequencing and isolation circuitry suppress lines surges, preventing voltage dips on the backplane communication bus that could trigger adjacent controller resets.\u003c\/p\u003e\n\u003cp\u003eQ: How do the +3.4 VDC and +12 VDC output channels adapt to high ambient temperatures?\u003c\/p\u003e\n\u003cp\u003eA: The +3.4 VDC rail maintains a continuous 2.0 A capacity up to +60 deg C. The dual +12 VDC rails supply up to 8.0 A and 6.0 A respectively across the complete -40 deg C to +70 deg C hardware operating specification under continuous thermal load.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCarrier Baseplate Alignment\u003c\/strong\u003e: Position the module hooks into the designated slots of the S-Series power carrier assembly. Press the component perpendicularly onto the backplane connectors until the mechanical retention latch engages completely.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Cable Termination\u003c\/strong\u003e: Terminate the incoming 24 VDC supply conductors using certified pressure-clamp connections. Ensure all terminal connection points are torqued down to factory specifications to minimize contact resistance and local heating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShield Ground Maintenance\u003c\/strong\u003e: Terminate all external supply ground lines and shield runs at the main cabinet common ground bar. Single-point grounding must be verified to prevent circulating current loops from interfering with low-voltage logic paths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Management Clearances\u003c\/strong\u003e: Ensure the ventilation slots on the module chassis remain unblocked. When deploying in environments with Class G3 contaminants, maintain sealed cabinet parameters with positive-pressure air circulation to prevent airborne tracking breakdown.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52921810944309,"sku":"KJ1501X1-BK1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/KJ3241X1-BK1_33d6abdb-b180-436d-b537-e41ddfc56fba.png?v=1779693685","url":"https:\/\/www.5gplc.com\/products\/emerson-kj1501x1-bk1-deltav-system-power-supply","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}