{"product_id":"emerson-epro-mms-3110-011-000-dual-channel-shaft-vibration-transmitter","title":"Emerson Epro MMS 3110\/011-000 Dual-Channel Shaft Vibration Transmitter","description":"\u003cp\u003eConfigured for rotational displacement acquisition in MMS 3000 machinery monitoring platforms, the \u003cstrong\u003eEmerson Epro MMS 3110\/011-000\u003c\/strong\u003e (\u003cstrong\u003eMMS 3110\/011-000\u003c\/strong\u003e) Dual-Channel Shaft Vibration Transmitter provides direct electrical execution of dual-channel eddy-current signal conditioning and current output transmission.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMMS 3110\/011-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson Epro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eRedundant 24 VDC inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eEddy current sensors (PR6422\/23\/24\/25)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003e0\/4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe MMS 3110\/011-000 is engineered for high-precision shaft vibration monitoring, requiring strict adherence to eddy-current probe scaling protocols during integration. During installation, operators must perform gap voltage validation against -10 VDC targets to ensure that the transducer remains within the linear measurement region of the shaft target. The module architecture incorporates cross-talk suppression by utilizing independent signal processing paths for the two channels, which prevents parasitic signal coupling and ensures the accuracy of peak value output calculations in high-speed rotor applications.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support hot-swapping under power?\u003c\/p\u003e\n\u003cp\u003eA: The transmitter hardware is designed for fixed installation. Removal or insertion while the 24 VDC redundant power rails are energized is not recommended, as transient current spikes may occur on the analog output loops.\u003c\/p\u003e\n\u003cp\u003eQ: How is the output characteristic configured?\u003c\/p\u003e\n\u003cp\u003eA: Frequency ranges and signal scaling are defined via internal DIP switches or software configuration. Changes to these parameters must be verified against the machine's specific rotational frequency and dynamic response requirements before the unit is returned to service.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the IP65-rated transmitter enclosure on a rigid surface near the machine to minimize cable run lengths from the eddy-current probes.\u003c\/li\u003e\n\u003cli\u003eTerminate sensor coaxial cabling with proper impedance matching to the PR642x series probes; ensure the shield is connected to the designated ground terminal to maintain signal integrity.\u003c\/li\u003e\n\u003cli\u003eWire the redundant 24 VDC inputs to separate power sources to maintain measurement availability in the event of a single supply failure.\u003c\/li\u003e\n\u003cli\u003eVerify the 0\/4-20 mA output linearity by simulating a static gap voltage and measuring the resulting loop current at the control system termination block.\u003c\/li\u003e\n\u003cli\u003eEnsure that all conduit entries are sealed correctly to maintain the IP65 environmental rating against ingress of dust or moisture.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53035976786229,"sku":"MMS 3110\/011-000","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/MMS3120022-1001_3c67cb8d-d0eb-4bf4-aa10-2ddefe63b743.png?v=1782373338","url":"https:\/\/www.5gplc.com\/products\/emerson-epro-mms-3110-011-000-dual-channel-shaft-vibration-transmitter","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}