{"product_id":"emerson-epro-con021-pr6424-010-040-eddy-current-sensor-kit","title":"Emerson Epro CON021+PR6424\/010-040 Eddy Current Sensor Kit","description":"\u003cp\u003eConfigured for high-precision displacement measurement in rotating machinery monitoring networks, the \u003cstrong\u003eEmerson Epro CON021+PR6424\/010-040\u003c\/strong\u003e (\u003cstrong\u003eCON021+PR6424\/010-040\u003c\/strong\u003e) Eddy Current Sensor Kit provides direct physical execution of radial and axial dynamic shaft displacement sensing.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON021+PR6424\/010-040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson Epro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg (System total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DIN-rail mount (Converter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 65 deg C (Converter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC external\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Integration\u003c\/h3\u003e\n\u003cp\u003eThe system utilizes eddy-current induction to measure the clearance between the probe tip and the metallic rotor surface. Precise rotor dynamics analysis requires accurate eddy-current probe scaling to ensure the conditioned output signal maintains a linear relationship with mechanical displacement. During installation, gap voltage validation targets must be verified at the module interface to position the sensor within its calibrated linear operating range. To minimize signal degradation, the system employs high-frequency shielding between the PR6424 transducer and the CON021 converter. Effective cross-talk suppression is achieved by maintaining high-integrity coaxial connections, ensuring that electromagnetic interference does not corrupt dynamic waveform acquisition required for shaft position and vibration analysis.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the CON021 signal converter compatible with any proximity probe?\u003c\/p\u003e\n\u003cp\u003eA: No. The CON021 is designed specifically for integration with Epro-compatible proximity probes and extension cables. The system calibration is dependent on the matched impedance of the specific transducer and signal chain.\u003c\/p\u003e\n\u003cp\u003eQ: Can the CON021 converter be used in a hot-swappable configuration?\u003c\/p\u003e\n\u003cp\u003eA: Ensure power is isolated from the module terminal block prior to installation or removal. While the electronics are designed for industrial cabinet use, hot-swapping under power may induce voltage transients that could damage input circuitry or disrupt the current loop output.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Mounting\u003c\/strong\u003e: Secure the PR6424 probe in a rigid, vibration-isolated bracket to ensure that all measured displacement is relative to the shaft and not the sensor housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGap Adjustment\u003c\/strong\u003e: Establish the nominal air gap using a feeler gauge. Position the sensor tip to allow for the full operational range of shaft thermal expansion and dynamic movement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding\u003c\/strong\u003e: Route the coaxial cable away from high-current conductors and variable frequency drive (VFD) outputs. Terminate cable shields at a centralized instrument ground bus to mitigate noise induction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Termination\u003c\/strong\u003e: Utilize the screw terminals on the CON021 for field connections. Ensure that wiring is properly strain-relieved and that all connections are tightened to the specified torque to prevent intermittent signal loss from vibration.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53011423691061,"sku":"CON021+PR6424\/010-040","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON021_PR6423014-010_4f0bf5fe-acf5-4a2e-b186-86d9a7edcac8.png?v=1781762408","url":"https:\/\/www.5gplc.com\/products\/emerson-epro-con021-pr6424-010-040-eddy-current-sensor-kit","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}