{"product_id":"emerson-deltav-kl3003x1-ba1-digital-input-charm","title":"Emerson DeltaV KL3003X1-BA1 Digital Input CHARM","description":"\u003cp\u003eConfigured for discrete signal acquisition in DeltaV I\/O subsystems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eEmerson KL3003X1-BA1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eKL3003X1-BA1\u003c\/strong\u003e) Digital Input CHARM (Characterization Module) provides direct physical\/electrical execution of dry contact sensing.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKL3003X1-BA1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEmerson\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.04 kg (0.08 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard CHARM form factor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBus Power 32 mA at 6.3 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDry Contact\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eField Circuit\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 mA at 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control: Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe KL3003X1-BA1 CHARM provides channel-to-channel isolation within the DeltaV I\/O carrier, preventing electrical interference between individual field loops. This isolation is integral to the CHARM architecture, ensuring that faults in a single dry contact loop do not propagate to the common bus or affect adjacent input channels. The module processes field-side dry contact status and provides a 24 VDC wetting voltage for the field loop, converting the signal for transmission across the I\/O bus. Proper termination of the dry contact loop at the terminal block is required to maintain the integrity of the galvanic isolation barrier.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What is the purpose of the CHARM module in the DeltaV system?\u003c\/p\u003e\n\u003cp\u003eA: The Characterization Module (CHARM) allows for per-channel I\/O type assignment. The KL3003X1-BA1 specifically converts a dry contact field input into a digital signal that the DeltaV controller can process, eliminating the need for traditional multi-channel I\/O cards.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module hot-swappable?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The CHARM architecture supports hot-swapping. The module can be removed and replaced while the carrier is energized without affecting the operation of other channels in the same carrier.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstallation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAlign the module with the carrier slot and press firmly until the locking mechanism engages. Ensure the module is seated fully to maintain backplane communication contact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDry contact field wiring must be terminated on the CHARM terminal block. Use shielded twisted pair cable for field wiring to mitigate induced noise, and ensure the shield is grounded at the designated cabinet grounding bar.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe carrier system must be properly bonded to the system common earth ground. This is vital for the effective operation of the channel-to-channel isolation barrier and protection against electrostatic discharge.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVerification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVerify that the field loop resistance matches the required specifications for dry contact closure before applying power to the carrier. Ensure no foreign voltage is present on the dry contact field lines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52924096741685,"sku":"KL3003X1-BA1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/KL3003X1-BA1.png?v=1779775503","url":"https:\/\/www.5gplc.com\/products\/emerson-deltav-kl3003x1-ba1-digital-input-charm","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}