{"product_id":"emerson-con021-916-200-pr6426-000-130-eddy-current-signal-converter-system","title":"Emerson CON021\/916-200+PR6426\/000-130 Eddy Current Signal Converter System","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson CON021\/916-200+PR6426\/000-130\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCON021\/916-200+PR6426\/000-130\u003c\/strong\u003e Eddy Current Sensor System, operates as a dedicated hardware component for high-temperature shaft displacement measurement within MMS 6000\/3000 series platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON021\/916-200+PR6426\/000-130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBase Model\u003c\/td\u003e\n\u003ctd\u003eCON011\/CON021 Probe Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eProbe: Up to +180 deg C continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePowered via converter backplane \/ loop connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003eApprox 2.0 mm (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e8 V\/mm (200 mV\/mil) with 20 m calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003eStandardized analog voltage, 0 to -20 VDC (-2 VDC to -18 VDC linear)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Calibration Length\u003c\/td\u003e\n\u003ctd\u003eExactly 20.0 m total cable run\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure \u0026amp; Protection\u003c\/td\u003e\n\u003ctd\u003eConverter: Shielded aluminum DIN-rail; Probe: Up to 50 bar pressure rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Armor Option\u003c\/td\u003e\n\u003ctd\u003eStainless steel flexible armored conduit (130) with FEP\/PFA insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFOUNDATION Fieldbus \/ Profibus PA Connectivity and CJC Limits\u003c\/h3\u003e\n\u003cp\u003eThe CON021\/916-200 signal converter functions as an oscillator and demodulator module, generating high-frequency excitation for the PR6426 sensor head across long cable runs. The signal output interfaces with upstream process automation backplanes and fieldbus networks, maintaining signal fidelity across a calibrated 20-meter transmission path. Galvanic decoupling reduces common-mode voltage interference and channel cross-talk when integrating outputs into remote DCS infrastructure or 4-20 mA HART instrumentation loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the total system cable length calibrated between the PR6426 probe and CON021 converter?\u003c\/p\u003e\n\u003cp\u003eA: The CON021\/916-200 driver is factory-calibrated for an exact total system length of 20.0 meters, combining the integral probe lead and extension cabling to preserve specified linearity and 8 V\/mm sensitivity.\u003c\/p\u003e\n\u003cp\u003eQ: What environmental limits apply to the PR6426\/000-130 sensor head in field applications?\u003c\/p\u003e\n\u003cp\u003eA: The PR6426 displacement probe withstands continuous ambient temperatures up to +180 deg C and static pressures up to 50 bar inside heavy-duty turbine bearing housings.\u003c\/p\u003e\n\u003cp\u003eQ: What mounting format is utilized for the CON021 signal converter housing?\u003c\/p\u003e\n\u003cp\u003eA: The CON021 converter is housed in a shielded aluminum chassis designed for standard industrial DIN-rail mounting inside marshalling cabinets or junction boxes.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the 8 mm PR6426 probe head into the bearing housing, securing the threaded body to prevent mechanical loosening under high vibration.\u003c\/li\u003e\n\u003cli\u003eVerify physical gap clearance against shaft static position to ensure initial probe positioning falls within the -2 VDC to -18 VDC linear window.\u003c\/li\u003e\n\u003cli\u003eRoute the flexible stainless steel armored conduit lead away from sharp edges and hot piping to maintain FEP\/PFA insulation integrity.\u003c\/li\u003e\n\u003cli\u003eMount the CON021 converter module onto a grounded industrial DIN rail inside a low-vibration local junction box.\u003c\/li\u003e\n\u003cli\u003eConnect probe extension leads to the converter without altering or cutting the factory-calibrated 20.0-meter cable length, ensuring shield continuity to ground.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53331633766709,"sku":"CON021\/916-200+PR6426\/000-130","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON021_PR6424000-130_e28091c6-8ca6-4e71-bfac-5b4d2dc5b72c.png?v=1787121279","url":"https:\/\/www.5gplc.com\/products\/emerson-con021-916-200-pr6426-000-130-eddy-current-signal-converter-system","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}