{"product_id":"emerson-5xo0300g02-analog-output-module","title":"Emerson 5XO0300G02 Analog Output Module","description":"\u003cp\u003eConfigured for high-density signal distribution in Ovation control networks, the \u003cstrong\u003eEmerson 5XO0300G02\u003c\/strong\u003e (\u003cstrong\u003e5XO0300G02\u003c\/strong\u003e Analog Output Module) provides direct physical electrical execution for multi-channel voltage command signals. The hardware enables 16-bit resolution output across a range of -10 VDC to +10 VDC to support precise actuator and process control loop requirements.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5XO0300G02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.42 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e173 mm x 100 mm x 42 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Range\u003c\/td\u003e\n\u003ctd\u003e-10 VDC to +10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e250 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Instrumentation and Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e5XO0300G02\u003c\/strong\u003e integrates channel-to-channel isolation architecture to prevent common-mode noise propagation between distinct output circuits. This design ensures that electrical disturbances on one loop do not affect the signal integrity of adjacent channels. Furthermore, the module supports standard 4-20 mA HART loop protocol compatibility when utilized with appropriate signal converters, facilitating seamless integration with intelligent field devices within the Ovation ecosystem.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Is this module capable of hot-swapping during active process control?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the 5XO0300G02 is designed for hot-swap operations within the Ovation I\/O rack, allowing for module replacement without interrupting the backplane communication or de-energizing the entire system.\u003c\/p\u003e\n\u003cp\u003eQ: Does the 250 ms update rate represent the total throughput for all 16 channels?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the specified 250 ms update rate is the standard cycle time for the module to refresh the output registers across all 16 channels simultaneously.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eConfirm the 24 VDC power supply capacity is sufficient to handle the 200 mA draw under full-load conditions to prevent voltage sagging.\u003c\/li\u003e\n\u003cli\u003eEnsure the module is fully seated in the backplane slot; tighten the top and bottom retaining screws to establish a secure ground connection between the chassis and the rack.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for all field output wiring to prevent EMI interference, ensuring the shield drain is terminated at the designated cabinet ground bus.\u003c\/li\u003e\n\u003cli\u003eRoute output signal wiring separately from AC power and high-current relay control lines to maintain signal purity.\u003c\/li\u003e\n\u003cli\u003eVerify channel-to-channel polarity during termination to avoid short-circuiting the output stages.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52955216019765,"sku":"5X00300G02","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/5X00226G02_c7290934-bc19-4a76-a910-bc82c7564938.png?v=1780450551","url":"https:\/\/www.5gplc.com\/products\/emerson-5xo0300g02-analog-output-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}