{"product_id":"emerson-5x00502g01-analog-input-module","title":"Emerson 5X00502G01 Analog Input Module","description":"\u003cp\u003eConfigured for high-density signal acquisition in Ovation distributed control systems, the \u003cstrong\u003eEmerson 5X00502G01\u003c\/strong\u003e (\u003cstrong\u003e5X00502G01\u003c\/strong\u003e Analog Input Module) provides direct physical signal processing of analog field inputs. The module facilitates the conversion of field-level current, voltage, and RTD signals into digital format for controller logic execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5X00502G01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e250 mm x 150 mm x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003e4-20 mA, 0-10 V, RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.001% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e250 kOhm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eLoop Connectivity and Isolation\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e5X00502G01\u003c\/strong\u003e module incorporates advanced signal conditioning to support 4-20 mA HART loop protocol architectures. Each of the eight input channels provides channel-to-channel isolation to prevent ground loops and electrical interference common in large-scale industrial installations. The architecture supports configurable signal scaling and filtering, allowing the control system to normalize various input ranges effectively while maintaining a high common mode rejection ratio of 60 dB.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 5X00502G01 module support hot-swapping during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module is designed for hot-swapping within the Ovation backplane, allowing for replacement without de-energizing the entire I\/O rack.\u003c\/p\u003e\n\u003cp\u003eQ: How should the shield wires be terminated for optimal noise suppression?\u003c\/p\u003e\n\u003cp\u003eA: Shield wires must be terminated at the designated chassis ground point provided on the I\/O terminal block to minimize EMI\/RFI interference on the analog loops.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify backplane power is stable before inserting the module into the designated slot.\u003c\/li\u003e\n\u003cli\u003eAlign the module with the card guides and ensure the backplane connector is fully seated.\u003c\/li\u003e\n\u003cli\u003eSecure the module using the top and bottom captive screws to ensure a proper ground path between the module housing and the rack.\u003c\/li\u003e\n\u003cli\u003eTerminate field wiring according to the specific loop requirements (current, voltage, or RTD). Ensure all terminal connections are torqued to manufacturer specifications.\u003c\/li\u003e\n\u003cli\u003ePerform a cold junction compensation (CJC) calibration check if RTD inputs are utilized to ensure temperature measurement accuracy.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52953055330613,"sku":"5X00502G01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/5X00070G01_7b16369e-33cb-4b97-858a-554142226860.jpg?v=1780448677","url":"https:\/\/www.5gplc.com\/products\/emerson-5x00502g01-analog-input-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}