{"product_id":"emerson-5x00422g01-digital-input-module-16ch","title":"Emerson 5X00422G01 Digital Input Module | 16CH","description":"\u003cp\u003eConfigured for high-resolution Sequence of Events (SOE) recording in Ovation distributed control systems, the \u003cstrong\u003eEmerson 5X00422G01\u003c\/strong\u003e (\u003cstrong\u003e5X00422G01\u003c\/strong\u003e Digital Input Module) provides direct physical electrical execution for monitoring 16 isolated discrete channels. This module utilizes local hardware-based timestamping to capture state transitions with 1 ms resolution, eliminating network-induced latency for transient event analysis.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5X00422G01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 Isolated Digital Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Connectivity and Signal Isolation\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e5X00422G01\u003c\/strong\u003e architecture employs channel-to-channel and channel-to-backplane isolation to prevent electrical transients from disrupting the DCS logic bus. This robust isolation is necessary to maintain HART loop protocol signal integrity when integrated into mixed I\/O architectures. Furthermore, the module ensures accurate measurement in environments prone to electromagnetic interference (EMI) by utilizing hardware-based configurable debounce logic for contact chatter suppression, thereby maintaining valid process variable acquisition and diagnostic data exchange.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 5X00422G01 support hot-swapping during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports hot-swap functionality, allowing for removal or replacement without powering down the I\/O rack or interrupting the controller’s primary scan cycle. Ensure that all field-side wiring is secure and the system is in a controlled state prior to physical extraction.\u003c\/p\u003e\n\u003cp\u003eQ: How is the SOE data timestamp synchronized within the Ovation network?\u003c\/p\u003e\n\u003cp\u003eA: The module performs hardware-stamped timing at the point of signal detection. Synchronization is managed through the local hardware clock, which aligns with the global network master clock to ensure chronological consistency across distributed I\/O nodes.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect the backplane interface for pin stability and cleanliness before seating the module.\u003c\/li\u003e\n\u003cli\u003eAlign the module with the Ovation chassis rails and apply uniform pressure to ensure the connector fully mates with the backplane bus.\u003c\/li\u003e\n\u003cli\u003eTerminate all field signals at the designated screw terminal blocks, ensuring that external wiring supports the required sink or source orientation.\u003c\/li\u003e\n\u003cli\u003eUtilize shielded, twisted-pair cabling for field signals and bond the shields to the cabinet ground bus at the entry point to mitigate common-mode noise.\u003c\/li\u003e\n\u003cli\u003eVerify the module \"OK\" status LED and individual channel indicators post-installation to confirm proper communication with the central Ovation controller.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52955469906229,"sku":"5X00422G01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/5X00422G01.png?v=1780458410","url":"https:\/\/www.5gplc.com\/products\/emerson-5x00422g01-digital-input-module-16ch","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}