{"product_id":"emerson-5x00121g01-rtd-input-pmod","title":"Emerson 5X00121G01 RTD Input PMOD","description":"\u003cp\u003eConfigured for high-precision temperature data acquisition in Ovation control platforms, the \u003cstrong\u003eEmerson 5X00121G01\u003c\/strong\u003e (\u003cstrong\u003e5X00121G01\u003c\/strong\u003e) provides direct physical execution of 8-channel RTD signal conversion to digital data.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5X00121G01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e12 cm x 3 cm x 9.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial standard range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem-dependent load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e8-Channel RTD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCold Junction Compensation (CJC)\u003c\/h3\u003e\n\u003cp\u003eThe 5X00121G01 module performs signal conditioning for Resistance Temperature Detectors (RTDs), facilitating the conversion of resistive values into digitized process variables. The module design maintains channel-to-channel isolation to ensure that fluctuations in one sensor loop do not introduce noise into adjacent measurement channels. While the module is dedicated to RTD inputs, it adheres to the standardized Ovation input architecture, supporting robust signal integrity for thermocouple or RTD-based temperature monitoring applications. Cold junction compensation (CJC) parameters are managed via the Ovation controller software to ensure accurate temperature linearization and calibration across all 8 channels.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 5X00121G01 support hot-swap operations within the I\/O chassis?\u003c\/p\u003e\n\u003cp\u003eA: The module is compatible with hot-swap procedures provided by the Ovation I\/O rack design. Operators must inhibit the specific input points within the engineering software prior to extraction to prevent system-wide diagnostic errors or the transmission of incorrect process data.\u003c\/p\u003e\n\u003cp\u003eQ: Is field-side calibration required after replacing the 5X00121G01?\u003c\/p\u003e\n\u003cp\u003eA: Verification of input accuracy is recommended post-installation. Compare the digitized output at the workstation against a calibrated temperature source to confirm that the signal conditioning is within the specified tolerance for the RTD type configured in the control database.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the I\/O rack is in a de-energized or maintenance-inhibited state before installing the PMOD into the designated slot.\u003c\/li\u003e\n\u003cli\u003eAlign the module with the chassis guide rails and seat the connector firmly to establish the backplane bus interface.\u003c\/li\u003e\n\u003cli\u003eTerminate RTD field wiring to the module terminal blocks, ensuring that all lead-wire resistance is accounted for according to the wiring diagram (e.g., 3-wire or 4-wire configuration).\u003c\/li\u003e\n\u003cli\u003eConnect the cable shields to the designated cabinet ground point to minimize common-mode noise impact on high-sensitivity RTD signals.\u003c\/li\u003e\n\u003cli\u003eConfirm that the module status LED indicates proper communication with the I\/O processor and verify the input signal values on the Ovation HMI.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52952869896501,"sku":"5X00121G01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/5X00121G01.png?v=1780387657","url":"https:\/\/www.5gplc.com\/products\/emerson-5x00121g01-rtd-input-pmod","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}