{"product_id":"emerson-5x00119g03-temperature-module","title":"Emerson 5X00119G03 Temperature Module","description":"\u003cp\u003eConfigured for precision thermal signal acquisition in Ovation distributed control systems, the \u003cstrong\u003eEmerson 5X00119G03\u003c\/strong\u003e (\u003cstrong\u003e5X00119G03\u003c\/strong\u003e Temperature Module) provides direct physical electrical execution for multi-channel input processing. The module interface handles both thermocouple and Resistance Temperature Detector (RTD) signals, maintaining measurement accuracy across temperature ranges from -200 deg C to 850 deg C, depending on the sensor type connected.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5X00119G03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Ovation Module Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003eMulti-channel (8 or 16)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel Isolation and Cold Junction Compensation\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e5X00119G03\u003c\/strong\u003e architecture utilizes channel-to-channel and channel-to-system isolation to suppress common-mode noise and prevent ground loops within the control loop. For thermocouple inputs, the module incorporates cold junction compensation (CJC) circuitry to ensure precise reference temperature tracking. This isolation framework is required to maintain the specified measurement accuracy in industrial environments characterized by high electromagnetic interference, ensuring that validated temperature data is transmitted to the Ovation controller bus without degradation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 5X00119G03 support hot-swapping during normal system operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports hot-swap functionality. Ensure that field wiring is secured and the system configuration mode is set to maintenance to avoid signal noise during module insertion or removal.\u003c\/p\u003e\n\u003cp\u003eQ: How is the thermocouple or RTD type selected for each channel?\u003c\/p\u003e\n\u003cp\u003eA: Sensor type selection and channel configuration are performed within the Ovation control system software environment. Ensure the appropriate I\/O channel configuration profile is applied to match the connected field hardware.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect the backplane interface slot for pin integrity and absence of debris before installing the module.\u003c\/li\u003e\n\u003cli\u003eAlign the module with the Ovation rack chassis rails and seat it firmly until the mechanical locking lever is fully closed.\u003c\/li\u003e\n\u003cli\u003eTerminate field signal wiring at the dedicated terminal block, ensuring proper polarity for thermocouples or lead-wire configuration for RTDs.\u003c\/li\u003e\n\u003cli\u003eRoute all sensor cabling using shielded, twisted-pair conductors and ground the shield drain wires to the cabinet common ground bus to maintain noise immunity.\u003c\/li\u003e\n\u003cli\u003eVerify the operational status through the front-panel LED indicators and confirm that the controller acknowledges the module presence after the hardware installation is complete.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52955451228469,"sku":"5X00119G03","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/1C31129G01_6419bde0-025b-48ca-a528-e8eeadb621c0.png?v=1780457595","url":"https:\/\/www.5gplc.com\/products\/emerson-5x00119g03-temperature-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}