{"product_id":"emerson-5x00119g02-temperature-module","title":"Emerson 5X00119G02 Temperature Module","description":"\u003cp\u003eConfigured for precision thermal signal acquisition in Ovation distributed control systems, the \u003cstrong\u003eEmerson 5X00119G02\u003c\/strong\u003e (\u003cstrong\u003e5X00119G02\u003c\/strong\u003e) Temperature Module provides direct physical electrical execution for processing 8 RTD input channels. The hardware facilitates temperature monitoring across ranges from -200 deg C to 850 deg C, depending on the specific Resistance Temperature Detector (RTD) type connected to the field interface.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5X00119G02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Ovation Module Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003ePer Ovation Standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem Powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e8 RTD Inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eCold Junction Compensation and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e5X00119G02\u003c\/strong\u003e implements internal signal processing to support precise RTD measurement, requiring accurate lead-wire compensation to mitigate measurement errors induced by resistive heating in field cabling. The architecture utilizes channel-to-channel isolation to prevent ground loops and electrical interference from degrading signal accuracy in high-noise industrial environments. This design maintains measurement integrity for low-level resistance inputs, ensuring that the Ovation controller receives validated temperature data for control loop execution.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 5X00119G02 support hot-swapping during active system operation?\u003c\/p\u003e\n\u003cp\u003eA: The module supports hot-swap functionality within the Ovation I\/O rack. Ensure that all field wiring is isolated and the I\/O configuration is set to manual or maintenance mode to prevent process disturbances during the removal or insertion of the module.\u003c\/p\u003e\n\u003cp\u003eQ: How should 3-wire or 4-wire RTD configurations be terminated?\u003c\/p\u003e\n\u003cp\u003eA: Terminations must follow the specific Ovation terminal block wiring diagrams to ensure proper lead-wire resistance compensation. Ensure that all shield drain wires are connected to the designated ground bus to minimize noise pickup.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eInspect the backplane slot for connector integrity before installing the 5X00119G02 module.\u003c\/li\u003e\n\u003cli\u003eAlign the module with the Ovation rack guide rails and press until the mechanical locking mechanism is fully engaged.\u003c\/li\u003e\n\u003cli\u003eTerminate RTD field inputs at the terminal assembly, ensuring wire gauge and length conform to system specifications for resistance tolerance.\u003c\/li\u003e\n\u003cli\u003eVerify all signal shields are grounded at a single common point within the cabinet to prevent circulating ground currents between channels.\u003c\/li\u003e\n\u003cli\u003ePerform an I\/O loop check using a calibrated resistance simulator to verify the module input scaling and channel integrity prior to process integration.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52955353317685,"sku":"5X00119G02","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/5X00622G01_3ede570f-1bca-4ce0-bc46-fef7a5bde3d6.png?v=1780455199","url":"https:\/\/www.5gplc.com\/products\/emerson-5x00119g02-temperature-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}