{"product_id":"dspc173-57310001-mt-abb-repeater-module","title":"DSPC173 57310001-MT | ABB | Repeater Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB DSPC173 57310001-MT\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eDSPC173\u003c\/strong\u003e Repeater Module, operates as a dedicated hardware component for localized control logic execution within ABB bus networks. Configured for signal amplification and electrical isolation across extended bus topologies, the assembly reconstructs degraded transmission signals to provide direct physical\/electrical execution of real-time communication frames.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eDSPC173 57310001-MT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSwitzerland \/ Sweden (Standard production origin matrix)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e254 mm x 254 mm x 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C (Nominal industrial standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem backplane bus powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe internal signal conditioning circuits of the \u003cstrong\u003eABB DSPC173 57310001-MT\u003c\/strong\u003e are calibrated to maintain strict alignment with design-specified backplane bus communication velocity metrics. When bridging segmented local architecture fields to broader Profinet or EtherNet\/IP deterministic networks, the hardware minimizes propagation delay and prevents packet collision. The physical sub-assembly configuration isolates noise vectors during massive I\/O density scaling phases, ensuring that local node branch extensions operate reliably within the bounds of host controller firmware flash compatibility parameters.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is hot-swapping or live extraction of the DSPC173 repeater card supported while the system backplane is energized?\u003c\/p\u003e\n\u003cp\u003eA: No. The board lacks dedicated live-insertion isolation switches. Removing or re-inserting the hardware component while the bus segments are powered can introduce transient voltage arcs, potentially causing data corruption on adjacent network nodes or permanent physical trace damage.\u003c\/p\u003e\n\u003cp\u003eQ: How is signal link degradation diagnosed on the DSPC173 module?\u003c\/p\u003e\n\u003cp\u003eA: Status indication loops must be verified through the centralized system controller diagnostic registers. If attenuation faults occur, check for proper input voltage thresholds from the backplane and verify that the connected network lengths do not exceed maximum specified segment distances.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Handling Requirements\u003c\/strong\u003e: Field technicians must wear a properly grounded electrostatic discharge (ESD) wrist strap prior to removing the hardware from its shielding packaging to prevent latent dielectric breakdown.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Alignment and Fastening\u003c\/strong\u003e: Slide the card smoothly along the dedicated chassis enclosure guide channels to prevent pin deformation on the backplane interface. Tighten all front faceplate screws to maintain structural ground continuity under continuous plant vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Cable Routing Separation\u003c\/strong\u003e: Route all external network communication lines through separate low-voltage wireways. Maintain a physical clearance of at least 100 mm from power distribution conductors and variable frequency drive motor leads to mitigate inductive coupling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Control Verification\u003c\/strong\u003e: Ensure the module is situated in an IP 54 or better enclosure free from moisture condensation and airborne conductive soot to avoid physical tracking short-circuits on the unshielded circuit paths.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53105717936437,"sku":"DSPC173 57310001-MT","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/DSPC17357310001-MT.png?v=1783498728","url":"https:\/\/www.5gplc.com\/products\/dspc173-57310001-mt-abb-repeater-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}