{"product_id":"ds200sdccg1agd-ge-mark-v-series-drive-control-board","title":"DS200SDCCG1AGD | GE | Mark V Series Drive Control Board","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eDS200SDCCG1AGD\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprimary controller\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor General Electric's\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMark V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edrive systems. This high-performance Drive Control Board executes the core computational logic required to regulate industrial motor drives and turbine operations. By utilizing a multi-processor architecture, it ensures real-time data processing and synchronized system management. We offer this component as a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e, original GE product to guarantee maximum reliability for your critical infrastructure.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003eThe DS200SDCCG1AGD integrates advanced processing power with robust diagnostic hardware:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eComponent\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eTechnical Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGE General Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMark V Speedtronic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003ePrimary Function\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMain Drive Controller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProcessor Architecture\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThree (3) On-board Microprocessors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMulti-access RAM (Simultaneous Multi-processor Access)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eDiagnostic Interface\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTen (10) LED Fault Indicator Row\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eConfiguration Manual\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGEI-100029\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eProgramming\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupports Laptop-based Serial Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eParallel Processing Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThree dedicated microprocessors share access to the on-board RAM simultaneously. This architecture eliminates data bottlenecks and allows the board to execute complex control algorithms with minimal latency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstantaneous Fault Diagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eA row of ten LEDs provides immediate visual feedback. During normal operation, LEDs pulse in pairs from left to right. If a system failure occurs, the board triggers specific LED sequences to display precise fault codes, allowing technicians to identify issues without external tools.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eScalable Configuration Deployment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe DS200SDCCG1AGD supports centralized parameter management. Engineers can generate a single configuration file on a laptop and download it to multiple boards across different drives, ensuring system-wide consistency and reducing commissioning time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Voltage Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDesigned for the demanding environment of GE Motors and Industrial Systems, the board’s layout isolates low-voltage logic from the high-voltage drive components found within the cabinet.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Safety Protocol\u003c\/h3\u003e\n\u003cp\u003eDue to the critical nature of the Drive Control Board, engineers must follow these operational guidelines:\u003c\/p\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLethal Voltage Awareness:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHigh voltage exists across the board and cabinet components. Never touch any internal parts while the drive receives power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVisual Inspection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTo check board health, open the cabinet door and observe the LED sequence. A smooth left-to-right scan indicates healthy operation, while a static \"lit-up\" row signals a fault code.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eParameter Setup:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUpon installing a new board, you must configure the parameters to define how the microprocessors analyze data and regulate the drive. Use the tools provided in the GEI-100029 manual to ensure the board matches your specific motor requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow does the triple-processor system improve performance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe three microprocessors access the same RAM bank at the same time. This allows the board to handle I\/O processing, motor logic, and diagnostic monitoring in parallel rather than sequentially, significantly increasing response speed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat do the ten LEDs signify during a system error?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhen the board detects a malfunction, it utilizes the 10-LED row to display a binary or sequential fault code. Refer to the GEI-100029 manual to translate these visual patterns into specific hardware or software errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the same configuration for multiple DS200SDCCG1AGD boards?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. You can create a master configuration file on a laptop and download it to numerous boards. This feature is particularly useful for facilities managing multiple identical drive assemblies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs this board a refurbished or used unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. This listing is for a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoriginal GE unit. It has never been installed, ensuring that the microprocessors and RAM have zero previous operational wear.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52799973785909,"sku":"DS200SDCCG1AGD","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/DS200SDCCG1AGD.png?v=1777429826","url":"https:\/\/www.5gplc.com\/products\/ds200sdccg1agd-ge-mark-v-series-drive-control-board","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}