{"product_id":"d25-0158-000001-ge-fanuc-digital-i-o-module","title":"D25-0158-000001 | GE Fanuc | Digital I\/O Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc D25-0158-000001\u003c\/strong\u003e serves as the primary \u003cstrong\u003eD25\u003c\/strong\u003e Digital I\/O Module utilized to execute digital telemetry monitoring and contact output operations across industrial automation platforms. The hardware processes up to 96 optically isolated bipolar digital inputs grouped in 32-channel matrices, enabling precise Sequence of Events (SOE) tracking with 1 ms time-tagging. Concurrently, it drives downstream field devices through up to 32 relay outputs featuring select-check-before-execute software verification and single-component failure detection.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eD25-0158-000001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eTechnical specifications determine factory origin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eInternal hardware card configuration dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard D25 series rack envelope compatibility\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial grade environmental tolerance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDetermined by total active I\/O count and loop wetting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical Isolation (Inputs)\u003c\/td\u003e\n\u003ctd\u003e5000 Vrms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Ratings\u003c\/td\u003e\n\u003ctd\u003e125 Vdc \/ 250 V Vdc options \/ Tolerances: +\/-20%, bipolar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Burden\u003c\/td\u003e\n\u003ctd\u003e1.2 to 10 mA \/ Maximum power dissipation 0.5 W per input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime-Tagging Accuracy\u003c\/td\u003e\n\u003ctd\u003e1 ms resolution for Sequence of Events (SOE) data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWetting Source\u003c\/td\u003e\n\u003ctd\u003eOn-board wetting voltage provision integrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Configurations\u003c\/td\u003e\n\u003ctd\u003e16 or 32 relay channels \/ 1 Form A contact type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Switching Limits\u003c\/td\u003e\n\u003ctd\u003eMaximum 60 W or 125 VA (resistive load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltages\u003c\/td\u003e\n\u003ctd\u003e75 Vdc or 50 Vac (DB-25), 120 Vdc (FACE-40) maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Ratings\u003c\/td\u003e\n\u003ctd\u003e2 A maximum switching \/ 2 A maximum carrying\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Timing Profiles\u003c\/td\u003e\n\u003ctd\u003eOperate time: 5 ms \/ Release time: 5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Isolation Limits\u003c\/td\u003e\n\u003ctd\u003e1500 Vac for 1 minute (coil-to-contact); Inter-output: 300 Vdc (compression terminal block) or 100 Vdc (DB-25)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks Integration\u003c\/h3\u003e\n\u003cp\u003eThe module processor maintains internal register synchronization over the system backplane, ensuring absolute firmware flash compatibility when mapping high-density input channels. The hardware separates localized A\/D and digital state sampling from host network polling routines, allowing the three-level software filtering engine to suppress contact chatter without modifying the deterministic processing of the core logic. Pulse accumulator loops on up to 8 designated inputs scale independently from communication port traffic, preventing packet dropouts from affecting totals.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the D25-0158-000001 module cards be hot-swapped while the 120 Vdc or 250 Vdc wetting voltages are active on the field terminals?\u003c\/p\u003e\n\u003cp\u003eA: No. The internal backplane pins and signal traces do not feature live isolation barriers. All auxiliary and field power loops must be fully de-energized prior to removing or inserting modules to prevent transient voltage arcing or damage to the optical isolators.\u003c\/p\u003e\n\u003cp\u003eQ: How is the select-check-before-execute security handled if a single component fails inside the output circuitry?\u003c\/p\u003e\n\u003cp\u003eA: The onboard hardware architecture incorporates dual-path validation paths. If an internal component failure occurs within the activation driver, the module detects the diagnostic state mismatch during the \"check\" phase and blocks the final execution sequence, keeping the 1 Form A contact open.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Grounding Protection\u003c\/strong\u003e: Connect a low-impedance copper conductor from the chassis ground stud directly to the control cabinet master earth bus bar before connecting field wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Signal Separation\u003c\/strong\u003e: Route all 12 Vdc to 250 Vdc discrete input lines in separate wiring ducts away from high-power AC motor supply lines to reduce inductive noise coupling into the debounce filters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Isolation Boundaries\u003c\/strong\u003e: When utilizing DB-25 connector configurations, ensure the external voltage across adjacent channels does not exceed the 100 Vdc maximum isolation limit. Use compression terminal blocks if 300 Vdc inter-output isolation is required.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":53047652286773,"sku":"D25-0158-000001","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/D25-0159-000001_9915b9a9-cfdc-4c37-a78c-ee90e3a0e845.png?v=1782725290","url":"https:\/\/www.5gplc.com\/products\/d25-0158-000001-ge-fanuc-digital-i-o-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}