{"product_id":"crbx01-2vaa008424r1-abb-communication-module","title":"cRBX01 2VAA008424R1 ABB Communication Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB 2VAA008424R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ecRBX01\u003c\/strong\u003e Communication Module, operates as a dedicated hardware component for fiber optic signal repetition within remote bus extension topologies.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ecRBX01 2VAA008424R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden \/ Germany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.166 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e34 mm (Width) x 127 mm (Height) x 128 mm (Depth)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to +60 deg C (Standard industrial parameters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSourced via local system chassis backplane bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunctionality\u003c\/td\u003e\n\u003ctd\u003eFiber optic repeater for remote bus network extension\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Input Channels\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output Channels\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHS Code\u003c\/td\u003e\n\u003ctd\u003e85176200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Compliance\u003c\/td\u003e\n\u003ctd\u003eRoHS compliant (EU Directive 2011\/65\/EU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Category\u003c\/td\u003e\n\u003ctd\u003e5. Small Equipment (No external dimension more than 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe device functions as a physical-layer optical transceiver that re-clocks and amplifies data packets transferred over long-distance serial control links. By using dedicated internal optoelectronic arrays, the hardware maintains the native backplane bus communication velocity across segmented racks. This setup allows flexible I\/O density scaling options across remote nodes while preserving synchronization with primary Profinet or EtherNet\/IP deterministic networks, preventing data signal degradation and ensuring precise firmware flash compatibility across network nodes.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the cRBX01 communication module require independent software addressing on the network?\u003c\/p\u003e\n\u003cp\u003eA: No. The cRBX01 operates primarily as a physical-layer fiber optic repeater. It does not occupy a logical node address in the application firmware, allowing transparent transmission of data packets across the remote bus extension path.\u003c\/p\u003e\n\u003cp\u003eQ: What are the backplane constraints when extracting the module under live power conditions?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping capabilities depend on the specific hosting rack chassis specification. To prevent data corruption on remote sub-racks, the active network traffic must be rerouted or the linked communication channels put in a safe state before physical module extraction.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChassis Engagement\u003c\/strong\u003e: Insert the module into the designated slot on the DIN-rail assembly or backplane baseplate. Push firmly until the module connector engages completely with the terminal alignment blocks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFiber Optic Handling\u003c\/strong\u003e: Clean all optical fiber connector ferrules prior to insertion into the transceiver ports. Maintain the minimum specified bend radius for fiber optic cables inside the control enclosure to prevent signal attenuation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Protocol\u003c\/strong\u003e: Ensure the metal grounding clip on the module housing establishes a low-impedance connection with the cabinet structural steel frame to ensure effective electromagnetic immunity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53105522868533,"sku":"cRBX01 2VAA008424R1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CRBX01.png?v=1783494128","url":"https:\/\/www.5gplc.com\/products\/crbx01-2vaa008424r1-abb-communication-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}