{"product_id":"controledge-hc900-honeywell-900p01-0501-power-supply-module","title":"ControlEdge HC900 | Honeywell 900P01-0501 Power Supply Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 900P01-0501\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e900P01\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for localized AC-to-DC power conversion within ControlEdge HC900 controller racks. Configured to accept an input range of 120\/240 V AC, the unit delivers up to 60 W of regulated power directly to the rack backplane bus. This supply maintains operational power distribution to adjacent CPU, I\/O, and communication modules plugged into the rack chassis.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e900P01-0501\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.67 kg (1.47 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard ControlEdge HC900 rack power supply footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e60 W Output Capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120\/240 V AC (Auto-ranging \/ Selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eControlEdge HC900 Series Rack Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; DCS Power Integrity\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell 900P01-0501\u003c\/strong\u003e power supply module incorporates galvanic isolation between the incoming primary AC lines and the internal 5 VDC \/ 24 VDC backplane logic buses. Designed to protect sensitive process control circuits from line disturbances, the internal regulation loop suppresses field-side voltage spikes, electromagnetic interference, and brownout conditions. This power isolation prevents high-voltage AC surges on field supply terminals from propagating through the backplane into sensitive analog process variable channels or 4-20 mA HART loop protocol conversion hardware.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 900P01-0501 power supply module support hot-swapping or removal under power?\u003c\/p\u003e\n\u003cp\u003eA: No, AC primary power input lines connected directly to the module terminal block must be isolated and de-energized before removing or installing the power supply module to prevent electrical shock and backplane arc faults.\u003c\/p\u003e\n\u003cp\u003eQ: What happens if the total power load of the modules in the HC900 rack exceeds 60 W?\u003c\/p\u003e\n\u003cp\u003eA: Exceeding the 60 W threshold can trigger internal thermal or overcurrent protection, causing the power supply to enter a foldback or shutdown mode. System power calculations must be verified using the HC900 rack configuration tool prior to powering the rack.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure primary 120\/240 V AC supply power is completely disconnected at the main breaker panel before wiring the terminal block of the 900P01-0501.\u003c\/li\u003e\n\u003cli\u003eConnect a dedicated ground wire from protective earth to the module's grounding terminal to ensure proper noise suppression and safety isolation.\u003c\/li\u003e\n\u003cli\u003eMaintain minimum vertical clearance above and below the power supply chassis within the enclosure to facilitate natural convection cooling and prevent thermal derating.\u003c\/li\u003e\n\u003cli\u003eEnsure all terminal block screws are torqued properly according to standard cabinet assembly requirements to prevent high-resistance terminal overheating.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":53531509063989,"sku":"900P01-0501","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/900P01-0401_122d30e1-4cd3-445f-8067-de0ba46832e4.png?v=1789094417","url":"https:\/\/www.5gplc.com\/products\/controledge-hc900-honeywell-900p01-0501-power-supply-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}