{"product_id":"con031-pr6423-000-101-emerson-epro-eddy-current-signal-converter-and-sensor-systems","title":"CON031+PR6423\/000-101 Emerson EPRO Eddy Current Signal Converter and Sensor Systems","description":"\u003cp\u003eConfigured for high-frequency dynamic displacement signal processing in machinery monitoring networks, the \u003cstrong\u003eEmerson CON031+PR6423\/000-101\u003c\/strong\u003e (\u003cstrong\u003eCON031+PR6423\/000-101\u003c\/strong\u003e Eddy Current Signal Converter and Sensor Systems) provides direct physical signal conditioning and electromagnetic gap execution. The converter and probe assembly processes shaft position shifts into high-linearity analog voltage signals across rotating equipment protection loops.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON031+PR6423\/000-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eSensor: -35 to +180 deg C (head\/1 m cable), Cable: -35 to +150 deg C, Converter: -30 to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePower supplied via rack monitor backplane or external supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range (-3 dB)\u003c\/td\u003e\n\u003ctd\u003e0 to 20000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise Time\u003c\/td\u003e\n\u003ctd\u003eLess than 15 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Cable Length\u003c\/td\u003e\n\u003ctd\u003e4.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Termination\u003c\/td\u003e\n\u003ctd\u003eOpen cable end\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Shaft Diameter\u003c\/td\u003e\n\u003ctd\u003e25 mm (0.79 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Target Material\u003c\/td\u003e\n\u003ctd\u003eFerromagnetic Steel 42CrMo4 (AISI\/SAE 4140)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eSensor: IP66 (IEC 60529); Converter: IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eCON031 compatible with PR6422, PR6423, PR6424, PR6426\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEddy Current Signal Converter and Sensor Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe CON031 signal converter utilizes channel-to-channel isolation architecture to prevent common-mode ground noise from invalidating wide-bandwidth vibration data across the 0 to 20000 Hz frequency range. When interfaced with process automation networks operating 4-20 mA HART loop protocol instruments or FOUNDATION Fieldbus nodes, the converter keeps signal conditioning circuits galvano-isolated from main plant supply buses. Internal thermal compensation circuits manage temperature shifts, stabilizing cold junction compensation references and ensuring precise dynamic response during rapid thermal transients.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the CON031 converter be paired with a PR6425 probe for extended range applications?\u003c\/p\u003e\n\u003cp\u003eA: No, the PR6425 probe strictly requires an extended range signal converter such as the CON021\/91x-xxx series to match its calibration envelope.\u003c\/p\u003e\n\u003cp\u003eQ: What precautions must be observed regarding the open cable end on the PR6423\/000-101 probe?\u003c\/p\u003e\n\u003cp\u003eA: The open cable end must be properly landed in a terminal block with outer shield wire grounded at one point inside an IP-rated junction box to prevent RF noise coupling.\u003c\/p\u003e\n\u003cp\u003eQ: How does target material composition impact the output calibration of the CON031 converter?\u003c\/p\u003e\n\u003cp\u003eA: The system is factory calibrated to Ferromagnetic Steel 42CrMo4 (AISI\/SAE 4140). Using alternative shaft alloys alters magnetic permeability and requires recalibration of the scale factor.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the CON031 signal converter onto a 35 mm DIN rail inside a protective enclosure, maintaining an IP20 environment and operating temperatures between -30 and +100 deg C.\u003c\/li\u003e\n\u003cli\u003eInspect the target rotor shaft to verify a minimum shaft diameter of 25 mm and confirm material specification matches 42CrMo4 ferromagnetic steel.\u003c\/li\u003e\n\u003cli\u003eMount the PR6423 probe head perpendicular to the shaft, maintaining correct thread engagement for the 25 mm case length.\u003c\/li\u003e\n\u003cli\u003eAdjust insertion depth to set the static mechanical air gap according to system baseline DC voltage specifications before tightening the outer locknut.\u003c\/li\u003e\n\u003cli\u003eConnect the 4.0 m open-ended cable conductors to the CON031 input terminals, ensuring the cable shield terminates at a single-point cabinet ground.\u003c\/li\u003e\n\u003cli\u003eRoute all probe signal cables in dedicated metallic conduit isolated from high-voltage AC motor cables.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53446190072117,"sku":"CON031+PR6423\/000-101","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON031_PR642300R-101_e842f0b5-83c6-47c4-b25a-a6ed9a4d6690.png?v=1788341996","url":"https:\/\/www.5gplc.com\/products\/con031-pr6423-000-101-emerson-epro-eddy-current-signal-converter-and-sensor-systems","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}