{"product_id":"con021-pr6424-01-eddy-current-sensor-kit-emerson-epro","title":"CON021+PR6424\/01 Eddy Current Sensor Kit | Emerson Epro","description":"\u003cp\u003eConfigured for non-contact displacement measurement in rotating machinery monitoring networks, the \u003cstrong\u003eEmerson Epro CON021+PR6424\/01\u003c\/strong\u003e (\u003cstrong\u003eCON021+PR6424\/01\u003c\/strong\u003e) Eddy Current Sensor Kit provides direct physical execution of radial and axial dynamic shaft displacement sensing.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON021+PR6424\/01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson Epro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg (System total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DIN-rail mount (Converter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 65 deg C (Converter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC external\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Integration\u003c\/h3\u003e\n\u003cp\u003eThe PR6424 sensor utilizes eddy-current induction to measure the gap between the probe tip and a metallic target. Precise rotor dynamics analysis requires accurate eddy-current probe scaling to ensure that the converted electrical signal maintains a linear relationship with mechanical displacement. During commissioning, gap voltage validation targets must be verified at the CON021 output to ensure the system is operating within its calibrated linear range. To preserve signal integrity across high-speed monitoring channels, the system employs internal cross-talk suppression by utilizing high-quality shielded cabling between the transducer and the converter, preventing electromagnetic noise from distorting the captured dynamic orbital motion and vibration signatures.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the CON021 signal converter be used with arbitrary cable lengths?\u003c\/p\u003e\n\u003cp\u003eA: No. The CON021 and PR6424 series components function as a factory-calibrated signal chain. Altering the total system length by modifying or replacing cables will change the resonant frequency and impedance of the circuit, introducing significant measurement errors.\u003c\/p\u003e\n\u003cp\u003eQ: How is the linear range affected by the 16 mm probe tip size?\u003c\/p\u003e\n\u003cp\u003eA: The 16 mm probe tip allows for a larger linear measurement range and an increased allowable operating gap compared to smaller probe diameters, which is appropriate for monitoring large-scale rotating equipment with higher thermal expansion or shaft run-out.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Install the CON021 converter on a standard DIN rail within a protective enclosure. Ensure the mounting is rigid to prevent mechanical vibration from influencing the signal conditioning circuitry.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGap Setting\u003c\/strong\u003e: Use a feeler gauge to establish the initial air gap between the probe tip and the shaft. Align the probe to the center of its linear range to accommodate total shaft displacement.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding\u003c\/strong\u003e: Terminate the cable shield at the designated instrument ground point. Proper shielding is required to reject common-mode electromagnetic interference (EMI) typical in industrial control environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring\u003c\/strong\u003e: Secure all field connections using the module's screw terminals. Verify that terminal tension is sufficient to withstand operational vibration, as intermittent contact will result in signal instability and false alarm triggering.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":53011416711477,"sku":"CON021+PR6424\/01","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON021_PR6424000-130_235ec9d5-ff6b-49e7-83ad-0dccf8636302.png?v=1781762172","url":"https:\/\/www.5gplc.com\/products\/con021-pr6424-01-eddy-current-sensor-kit-emerson-epro","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}