{"product_id":"con010-pr6423-010-120-emerson-eddy-current-sensor","title":"CON010+PR6423\/010-120 | Emerson | Eddy Current Sensor","description":"\u003cp\u003eConfigured for precision mechanical monitoring in rotating machinery, the \u003cstrong\u003eEmerson CON010 + PR6423\/010-120\u003c\/strong\u003e (\u003cstrong\u003eCON010 + PR6423\/010-120\u003c\/strong\u003e Eddy Current Sensor) provides direct physical electrical execution for shaft displacement and vibration measurement. The solution integrates the CON010 sensor module with the PR6423\/010-120 proximity probe to interface with Emerson EPRO monitoring platforms, facilitating real-time acquisition of dynamic shaft movement.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON010 + PR6423\/010-120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e21 cm x 20 cm x 3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Length\u003c\/td\u003e\n\u003ctd\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eCON010\u003c\/strong\u003e sensor module utilizes precise eddy-current probe scaling to translate electromagnetic induction changes into linear voltage signals corresponding to shaft gap distance. This process is required for accurate analysis of rotor dynamics, including radial vibration and axial position monitoring. The signal conditioning circuitry includes cross-talk suppression logic to maintain measurement integrity when multiple probes are installed in close proximity on a machine train. Operators must ensure proper gap voltage validation against the -10 VDC target range to maintain linearity within the transducer's dynamic operating range.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What is the recommended procedure for verifying the transducer gap voltage?\u003c\/p\u003e\n\u003cp\u003eA: During static conditions, adjust the probe mounting position until the output voltage reaches the nominal -10 VDC setpoint. This ensures the probe is operating in the linear region of its characteristic curve for both positive and negative shaft excursion.\u003c\/p\u003e\n\u003cp\u003eQ: Is this sensor system compatible with non-conductive shaft materials?\u003c\/p\u003e\n\u003cp\u003eA: Eddy current sensors require a conductive target. Measurement accuracy is dependent on the target material's electrical conductivity and magnetic permeability. Consult the probe calibration data for the specific material characteristics of the observed shaft.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the mounting bracket is rigid to prevent mechanical resonances from introducing measurement errors.\u003c\/li\u003e\n\u003cli\u003eVerify that the probe tip is installed perpendicular to the shaft surface to maintain consistent signal response across the entire dynamic range.\u003c\/li\u003e\n\u003cli\u003eUtilize shielded coaxial cabling between the probe and the CON010 module, and ensure the shield is bonded at the monitoring rack end to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003eAvoid routing probe signal cables in close proximity to high-current power cables or variable frequency drive (VFD) output leads to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003ePerform a static calibration check after installation to confirm that the gap voltage output matches the manufacturer-specified baseline for the installation clearance.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"EMERSON","offers":[{"title":"Default Title","offer_id":52956396388661,"sku":"CON010+PR6423\/010-120","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CON010_PR6423010-120.png?v=1780468389","url":"https:\/\/www.5gplc.com\/products\/con010-pr6423-010-120-emerson-eddy-current-sensor","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}