{"product_id":"cm579-pnio-abb-ac500-communication-module","title":"CM579-PNIO | ABB | AC500 Communication Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB CM579-PNIO 1SAP170901R0101\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCM579-PNIO\u003c\/strong\u003e Communication Module, operates as a dedicated hardware component for industrial Ethernet network coordination within AC500 PLC platforms. The module manages localized process data transfer via two integrated physical interfaces operating as a real-time hardware switch. Working at a specified data transmission rate of 100000 kbit\/s, the device directly executes PROFINET IO RT master or device cyclic frames and interfaces safety telegrams under the PROFIsafe sub-protocol specification.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCM579-PNIO (1SAP170901R0101)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e28 mm x 62 mm x 135 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to +60 deg C (Standard industrial parameters apply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupplied via AC500 CPU bus coupler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003ePROFINET IO RT Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003ePROFINET IO, PROFIsafe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardware Interfaces\u003c\/td\u003e\n\u003ctd\u003e2x Industrial Ethernet (Integrated Switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rate\u003c\/td\u003e\n\u003ctd\u003e100000 kbit\/s (100 Mbit\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks Mapping\u003c\/h3\u003e\n\u003cp\u003eThe ABB CM579-PNIO implements prioritized frame processing mechanisms to achieve precise transmission alignment with Profinet \/ EtherNet\/IP deterministic networks. The dual internal ports bypass standard commercial routing latency by utilizing a localized media access control architecture, validating consistent scan cycles across the synchronous PLC environment. This processing architecture provides predictable data synchronization profiles even when scaling local I\/O density demands on the multi-drop controller network.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the CM579-PNIO module support active hot-swapping into the AC500 terminal base during runtime?\u003c\/p\u003e\n\u003cp\u003eA: No, this communication module does not allow live insertion or removal. The entire local PLC segment must be de-energized before mounting or decoupling the card to prevent catastrophic data bus interruption or hardware latch-up constraints.\u003c\/p\u003e\n\u003cp\u003eQ: Can both Ethernet interfaces be assigned independent IP addresses on different network subnets?\u003c\/p\u003e\n\u003cp\u003eA: No, the two interfaces are connected through an integrated physical layer switch. They share identical MAC and IP configuration fields, functioning primarily to establish a daisy-chain linear topology without an external switch.\u003c\/p\u003e\n\u003cp\u003eQ: How does firmware flash compatibility affect PROFIsafe safety configurations on this card?\u003c\/p\u003e\n\u003cp\u003eA: Safety validation profiles dictate that any firmware flash adjustments on the controller base match the exact certified revision blocks listed within the safety parameters tool to prevent execution halts or default safe-state activations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe communication card must be locked directly onto the designated slot of the AC500 terminal base before sliding the assembly into place onto a standard, grounded structural DIN-rail. To fulfill standard industrial EMC constraints, connection to the integrated switch ports must utilize category 5e or higher shielded twisted-pair (STP) cabling. The grounding shield of the Industrial Ethernet wiring must hook into the physical frame structure via conductive spring clips. Ensure proper ventilation boundaries by retaining a minimum vertical displacement gap of 25 mm above and below the module face plate to prevent internal heat concentration.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53071539536181,"sku":"CM579-PNIO 1SAP170901R0101","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CM579-PNIO.png?v=1782974939","url":"https:\/\/www.5gplc.com\/products\/cm579-pnio-abb-ac500-communication-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}