{"product_id":"ci626v1-3bse012868r1-abb-communication-interface-module","title":"CI626V1 3BSE012868R1 ABB Communication Interface Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB CI626V1 3BSE012868R1\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCI626V1\u003c\/strong\u003e Communication Interface Module, operates as a dedicated hardware component for bridging ISA bus architectures and AF100 coaxial networks within Advant OCS and System 800xA platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCI626V1 (3BSE012868R1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e25.4 cm x 5.1 cm x 27.9 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e+5 to +55 deg C (AF100) \/ -40 to +70 deg C (PROFIBUS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.5 W (24 VDC supplied via system backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocols\u003c\/td\u003e\n\u003ctd\u003eAF100, PROFIBUS DP V1 (Master\/Slave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransmission Rate\u003c\/td\u003e\n\u003ctd\u003e9.6 kbps to 12 Mbps (auto-negotiation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Capacity\u003c\/td\u003e\n\u003ctd\u003eSupports up to 80 AF100 stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Interface\u003c\/td\u003e\n\u003ctd\u003eIntegrated coaxial media modems (supports 75-ohm coaxial cabling up to 700 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolation between field modems and internal interface logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eDIN rail or panel mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe CI626V1 module manages deterministic message routing between local controller backplanes and AF100 coaxial segments without compromising backplane bus communication velocity. Integrated hardware modems and galvanically isolated transceiver stages maintain high-speed signal integrity across distances up to 700 meters. Built-in firmware flash compatibility across Advant Master and System 800xA nodes allows seamless network expansion, ensuring predictable data update rates and reliable I\/O density scaling across redundant system topologies.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is power provided to the CI626V1 communication module?\u003c\/p\u003e\n\u003cp\u003eA: Power is drawn directly from the host system backplane at 24 VDC, with total module power dissipation rated at 2.5 W.\u003c\/p\u003e\n\u003cp\u003eQ: What physical cabling and maximum segment length are supported for the AF100 interface?\u003c\/p\u003e\n\u003cp\u003eA: The onboard integrated modems connect via standard 75-ohm coaxial cable, supporting point-to-point and bus segment distances up to 700 meters.\u003c\/p\u003e\n\u003cp\u003eQ: Is galvanic isolation integrated into the modem interfaces?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module features galvanic isolation positioned between the coaxial modems and internal logic circuitry to suppress ground loops and electrical transients.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the rack chassis and verify complete system electrical isolation prior to mounting or unseating the CI626V1 module.\u003c\/li\u003e\n\u003cli\u003eWear an ESD wrist strap connected to cabinet earth ground when handling the board assembly.\u003c\/li\u003e\n\u003cli\u003eSecure the chassis onto the DIN rail or panel mounting surface, ensuring the IP20 housing latches securely in place.\u003c\/li\u003e\n\u003cli\u003eAttach 75-ohm coaxial cables to the integrated media modem connectors, maintaining minimum cable bend radii and ensuring proper connector shield grounding.\u003c\/li\u003e\n\u003cli\u003eApply backplane power to the rack and verify network boot status via diagnostic LED indicators during initialization.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":53243286323509,"sku":"CI626V1 3BSE012868R1","price":66.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0973\/7630\/5461\/files\/CI6713BSE004043R1_1114df0c-99d7-4574-ba73-d7208c2c70a5.png?v=1785747855","url":"https:\/\/www.5gplc.com\/products\/ci626v1-3bse012868r1-abb-communication-interface-module","provider":"High Five PLC Solution Limited","version":"1.0","type":"link"}